DeltaTherm-11.21.pdf
Delt a Therm Infrared Heat Cur ing Chamber PV A ’s Delta T her m util izes infra red p anels to e cientl y cure adhes ives and coa tings in a contr olled , heated environme nt. T he Del ta Th erm fe ature s a double -si…

DeltaTherm
Infrared Heat Curing Chamber
PVA’s DeltaTherm utilizes infrared panels to eciently
cure adhesives and coatings in a controlled, heated
environment. The DeltaTherm features a double-sided
conguration and oers custom top and bottom heat
proling in each two foot section. Each infrared coated
panel is constructed for easy cleaning and maintenance.
An optional humidity control feature allows for further
control of moisture cure applications.
The DeltaTherm has many integrated features including:
• Edge carrying, variable speed pin chain conveyor
• Rail expansion compensation
• SMEMA communications interface
• PLC controller
• OIT touch panel with display screen
• Four-inch top and bottom side component clearance
• Thermocouple process control with independent
over temperature protection
• Optional humidity control
For more information, please contact PVA at
info@pva.net or (518) 371-2684.
System Specications
Power Requirements:
208 - 480 VAC, +/-10%, 50/60 Hz, 3Ø
Maximum Panel Temperature:
260º C (500º F)
Curing Length:
1.2 m / 2.4 m / 3.7 m / 4.8 m
(4 ft / 8 ft / 12 ft / 16 ft)
Independent Heating Zones:
Programmable in two foot sections
Conveyor Speed:
0.03 m/min to 15.24 m/min
(0.1 ft/min to 50 ft/min)
Board / Pallet Width:
50 mm to 500 mm
(1.9 in to 19.6 in)
Component Clearance:
100 mm (4 in) top and bottom
Conveyor Height:
890 mm to 965 mm from oor
(35 in to 38 in, SMEMA standard)
Exhaust:
DeltaTherm 4’: 200 CFM
DeltaTherm 8’: 300 CFM
DeltaTherm 8’ H: 140 CFM
DeltaTherm 12’: 600 CFM
DeltaTherm 12’ H: 210 CFM
DeltaTherm 16’: 1000 CFM
DeltaTherm 16’ H: 280 CFM
Alarm included
Certication:
CE
INNOVATION. PRECISION. EXCELLENCE.
REV C 11/12/20
Headquarters
6 Corporate Drive | Halfmoon, NY 12065
tel +1 518 371 2684 | fx +1 518 371 2688
www.pva.net | info@pva.net

All dimensions are provided in inches and millimeters.