N5227B.pdf - 第33页

Find us at www. keysi ght.com Page 33 Table 19 . Error Terms (dB), All Ports, All Options - Typical Description Directivity Source Match Load Match Transm ission Tracking Reflec tion Tracking Crosstalk 10 MHz to 50 M Hz …

100%1 / 90
Find us at www.keysight.com Page 32
Uncorrected System Performance
Specifications apply to following conditions:
Cable loss not included in Transmission Tracking.
Crosstalk measurement conditions: normalized to a thru, measured with shorts on all ports,
10 Hz IF bandwidth, averaging factor of 8, alternate mode, source power set to the specified
maximum power.
Table 17. Error Terms (dB), All Ports, All Options - Specifications
Description Directivity Source Match Load Match
Transmission
Tracking
Reflection
Tracking
Crosstalk
10 MHz to 50 MHz
1
17 (17)
7 (6) [7]
6 (6)
--
--
--
50 MHz to 500 MHz
1
24 (24)
15 (7) [6]
11 (7)
--
--
--
500 MHz to 2 GHz
24 (24)
10 (7) [6]
7 (7)
--
--
--
2 GHz to 3.2 GHz
20 (20)
10 (7) [8]
7 (7)
--
--
--
3.2 GHz to 10 GHz
20 (20)
7 (7) [7]
7 (7)
--
--
--
10 GHz to 16 GHz
16 (16)
7 (6) [7]
6 (6)
--
--
--
16 GHz to 20 GHz
16 (16)
7 (7) [7]
7 (7)
--
--
--
20 GHz to 26.5 GHz
14 (14)
7 (7) [7]
7 (7)
--
--
--
26.5 GHz to 50 GHz
13 (11)
7 (6) [7]
6 (6)
--
--
--
50 GHz to 60 GHz
13 (13)
7 (7) [6]
7 (7)
--
--
--
60 GHz to 67 GHz
10 (10)
6 (6) [5]
6 (6)
--
--
--
67 GHz to 70 GHz
--
--
--
--
--
--
( ) With an LFE option installed except for Source Match.
[ ] With option 220, 420 for Source Match only.
1
With an LFE option installed and LFE disabled, applied to frequencies <= 100 MHz. Above 100 MHz, performance is
the same for both LFE enabled or disabled. For LFE enabled performance <= 100 MHz, see Table 18.
Table 18. Error Terms (dB), All Ports, All LFE Options (LFE Enabled) - Specifications
Description Directivity Source Match Load Match
Transmission
Tracking
Reflection
Tracking
Crosstalk
1 kHz to 10 kHz
1
7
7
--
--
--
10 kHz to 1 MHz
16
15
19
--
--
--
1 MHz to 5 MHz
16
9
11
--
--
--
5 MHz to 50 MHz
5
7
8
--
--
--
50 MHz to 100 MHz
5
8
9
--
--
--
Find us at www.keysight.com Page 33
Table 19. Error Terms (dB), All Ports, All Options - Typical
Description Directivity Source Match Load Match
Transmission
Tracking
Reflection
Tracking
Crosstalk
10 MHz to 50 MHz
1
20 (20)
9 (9)
8 (8)
±1.0
±1.0
-88 (-81)
50 MHz to 200 MHz
1
28 (28)
19 (10)
17 (10)
±1.0
±1.0
-112 (-107)
200 MHz to 500 MHz
28 (28)
19 (8)
17 (8)
±1.0
±1.0
-129 (-121)
500 MHz to 2 GHz
31 (31)
14 (9)
12 (8)
±1.0
±1.0
-131 (-128)
2 GHz to 3.2 GHz
28 (28)
14 (13)
12 (12)
±1.0
±1.0
-127 (-124)
3.2 GHz to 10 GHz
25 (25)
11 (11)
10 (10)
±1.0
±1.0
-127 (-125)
10 GHz to 13.5 GHz
23 (23)
10 (10)
10 (10)
±1.0
±1.0
-127 (-125)
13.5 GHz to 16 GHz
23 (23)
11 (11)
11 (11)
±1.0
±1.0
-127 (-125)
16 GHz to 20 GHz
20 (20)
11 (11)
11 (11)
±1.0
±1.0
-127 (-125)
20 GHz to 26.5 GHz
18 (18)
11 (11)
11 (11)
±1.0
±1.0
-126 (-124)
26.5 GHz to 43.5 GHz
16 (16)
11 (11)
11 (11)
±1.0
±1.0
-112 (-111)
43.5 GHz to 50 GHz
19 (16)
11 (11)
11 (11)
±1.0
±1.0
-115 (-114)
50 GHz to 60 GHz
16 (16)
11 (11)
12 (12)
±1.0
±1.0
-111 (-110)
60 GHz to 67 GHz
16 (16)
9 (9)
10 (10)
±1.0
±1.0
-112 (-111)
67 GHz to 70 GHz
15 (15)
10 (10)
10 (10)
±1.0
±1.5
-109 (-108)
( ) With an LFE option installed.
1
With an LFE option installed and LFE disabled, applied to frequencies <= 100 MHz. Above 100 MHz, performance is
the same for both LFE enabled or disabled. For LFE enabled performance <= 100 MHz, see Table 20.
Table 20. Error Terms (dB), All Ports, All LFE Options
(LFE Enabled) - Typical
Description Directivity Source Match Load Match
Transmission
Tracking
Reflection
Tracking
Crosstalk
500 Hz to 900 Hz
--
--
--
--
--
-102
900 Hz to 1 kHz
4
8
9
±1.5
±1.5
-106
1 kHz to 10 kHz
5
9
8
±1.5
±1.5
-100
10 kHz to 100 kHz
23
19
23
±1.5
±1.5
-106
100 kHz to 1 MHz
23
19
23
±1.5
±1.5
-126
1 MHz to 5 MHz
26
13
14
±1.5
±1.5
-121
5 MHz to 10 MHz
11
9
10
±1.5
±1.5
-121
10 MHz to 50 MHz
11
9
10
±1.5
±1.5
-117
50 MHz to 100 MHz
11
11
11
±1.5
±1.5
-117
Find us at www.keysight.com Page 34
Test Port Output
See the block diagrams at the end of this document for all models and options.
Table 21. Frequency Information, All Options
Description Specification Typical
N5227B Frequency Range
10 MHz to 67 GHz
67 GHz to 70 GHz
N5227B Frequency Range (LFE Options)
900 Hz to 67 GHz
500 Hz to 900 Hz
Frequency Resolution
1 Hz
--
Frequency Accuracy
±0.7 ppm
--
Initial Frequency Accuracy
1
±0.2 ppm
±0.1 ppm
Frequency Stability --
±0.05 ppm, -10° to 70° C
2
±0.5 (first year)
3
±0.1 ppm/yr maximum
2
1
Verified after Factory Frequency Reference adjustment, or after adjustment at a Keysight Service Center.
2
Assumes no variation in time.
3
Assumes no variation in temperature. Stability generally improves over time.
Table 22. Maximum Leveled Power (dBm), All Ports - Specification
Description Option 200, 400 Option 201, 401 Option 219, 419
Port 1, Port 3
Port 2, Port 4
Port 1, Port 3
Port 2, Port 4
Port 1, Port 3
Port 2, Port 4
10 MHz to 50 MHz
10
10
10
10
9
9
50 MHz to 2 GHz
13
13
13
13
13
13
2 GHz to 3.2 GHz
10
13
10
13
9
13
3.2 GHz to 10 GHz
13
13
13
13
11
12
10 GHz to 13.5 GHz
12
12
11
11
9
9
13.5 GHz to 16 GHz
12
12
12
12
10
10
16 GHz to 19 GHz
11
11
10
10
8
8
19 GHz to 24 GHz
11
11
11
11
8
8
24 GHz to 26.5 GHz
11
11
11
11
7
7
26.5 GHz to 30 GHz
10
10
10
10
7
7
30 GHz to 32 GHz
9
9
7
7
5
5
32 GHz to 35 GHz
10
10
9
9
6
6
35 GHz to 40 GHz
5
5
5
5
1
1
40 GHz to 50 GHz
11
11
10
10
6
6
50 GHz to 64 GHz
11
11
10
10
5
5
64 GHz to 67 GHz
11
11
10
10
4
4