00193463-01 - 第118页

3 What to do when .. . User Manual SIPLACE S-25 HM 3.8 Component table, mobile Software Version SR.503.xx 04/2002 US Edition 118 3.8.2 Undocking the component t able Fig. 3.8 - 2 Undocking the mobile c omponent

100%1 / 226
User Manual SIPLACE S-25 HM 3 What to do when ...
Software Version SR.503.xx 04/2002 US Edition 3.8 Component table, mobile
117
3.8 Component table, mobile
3.8.1 Safety instructions for docking and undocking the mobile component table
WARNING 3
Æ Never reach into the gap between the component tables and the placement system frame
while the machine is running (item 1).
Æ Always check that the component table is docked on the placement system before connecting
or disconnecting the component table power cable at the socket on the placement system
(item 2).
Æ NEVER connect the component table connecting cable to the socket on the placement system
and then operate the component table via the external compressed air control unit (item 3).
Fig. 3.8 - 1 Safety instructions for the mobile component table
3 What to do when ... User Manual SIPLACE S-25 HM
3.8 Component table, mobile Software Version SR.503.xx 04/2002 US Edition
118
3.8.2 Undocking the component table
Fig. 3.8 - 2 Undocking the mobile component
User Manual SIPLACE S-25 HM 3 What to do when ...
Software Version SR.503.xx 04/2002 US Edition 3.8 Component table, mobile
119
Key to Fig. 3.8 - 2
(1) Communication interface connector
(2) Power supply connector for the component table
(3) Compressed air connection
(4) Component table bed
(5) Button for raising and lowering the component table bed
(6) Actuating tube
(7) Fold-down bracket
(8) Holes for the centering pins
(9) Centering pins
(10) Contact surfaces for the slide rails of the component table
(11) Horizontal tensioners
(12) Movable cover that ensures that the power supply and control cables are plugged in and
removed in the correct order.
Æ Click on the STOP PROCESSING PCB icon in the MAIN VIEW menu.
Æ The PCB in progress will be completed. The icons of the SINGLE FUNCTIONS menu will then
be activated.
Æ Click on the desired SINGLE FUNCTIONS GANTRY X icon (gantry 1 or 2).
Æ Click on the GANTRY FUNCTIONS icon.
Æ From this menu, click on the GO TO SET-UP POSITION button.
Æ The selected placement head will move across the PCB transport to prevent it being damaged
when the component table is changed.
Æ Open protective cover of the selected gantry.
Æ Open the side screens.
Æ Open the horizontal tensioners (item 11).
Æ Pull the two actuating tubes (item 6) towards you at the same time and lift up the bracket (item
7) to lock the raised component table bed in its top end position.
Æ Hold down the button (item 5) for raising the component table bed (item 4) until the component
table bed reaches its top end position.
Æ Unplug the component table power cable (item 2).
Æ Move the cover (item 12) sideways until you can unplug the control cable (item 1).
Æ Unplug the component table control cable (item 1).
Æ Disconnect the compressed air supply (item 3).
Æ Remove the component table.