4 Component handling User Manual SIPLACE S-25 HM 4.6 Component table, mobile Software Version SR.503.xx 04/2002 US Edition 150 4.6.3 Docking the component t able W ARNING 4 Check tha t the plac ement he ad is outside t h…

100%1 / 226
User Manual SIPLACE S-25 HM 4 Component handling
Software Version SR.503.xx 04/2002 US Edition 4.6 Component table, mobile
149
Key to Fig. 4.6 - 2
(1) Communication interface connector
(2) Power supply connector for the component table
(3) Compressed air connection
(4) Component table bed
(5) Button for raising and lowering the component table bed
(6) Actuating tube
(7) Fold-down bracket
(8) Holes for the centering pins
(9) Centering pins
(10) Contact surfaces for the slide rails of the component table
(11) Horizontal tensioners
(12) Movable cover that ensures that the power supply and control cables are plugged in and
removed in the correct order.
Æ Click on the STOP PROCESSING PCB icon in the MAIN VIEW menu.
Æ The PCB in progress will be completed. The icons of the SINGLE FUNCTIONS menu will then
be activated.
Æ Click on the desired SINGLE FUNCTIONS GANTRY X icon (gantry 1 or 2).
Æ Click on the GANTRY FUNCTIONS icon.
Æ From this menu, click on the GO TO SET-UP POSITION button.
Æ The selected placement head will move across the PCB transport to prevent it being damaged
when the component table is changed.
Æ Open protective cover of the selected gantry.
Æ Open the side screens.
Æ Open the horizontal tensioners (item 11)
Æ Pull the two actuating tubes (item 6) towards you at the same time and lift up the bracket (item
7) to lock the raised component table bed in its top end position.
Æ Hold down the button (item 5) for raising the component table bed (item 4) until the component
table bed reaches its top end position.
Æ Unplug the component table power cable (item 2).
Æ Move the cover (item 12) sideways until you can unplug the control cable (item 1).
Æ Unplug the component table control cable (item 1).
Æ Disconnect the compressed air supply (item 3).
Æ Remove the component table.
4 Component handling User Manual SIPLACE S-25 HM
4.6 Component table, mobile Software Version SR.503.xx 04/2002 US Edition
150
4.6.3 Docking the component table
WARNING 4
Check that the placement head is outside the range of the component table. 4
CAUTION 4
When docking the component table, ensure that the table bed is in its top end position and the
bracket (item 7) is folded up. 4
Æ Cut off the empty tapes for the feeders.
Æ Make sure that the contact surface (item 10) for the component table bed is clean.
Æ CAREFULLY push the component table into the placement system.
Æ Connect the compressed air supply (item 3).
Æ Plug in the control cable (item 1).
Æ Move the cover (item 12) over the control cable plug to expose the power supply socket.
Æ Plug in the power cable (item 2) for the component table.
Æ Pull the two actuating tubes (item 6) towards you at the same time and then lower the bracket
(item 7) in order to be able to lower the component table bed.
Æ Check that the centring holes in the component table bed lie precisely over the centering pins
of the placement system.
Æ Hold down the button (item 5) until the component table bed reaches its top end position.
Æ Release the button and the component table bed will descend.
Æ Ensure that the centring pins engage in the centring holes in the component table bed and that
the component table bed is fully lowered.
Æ Fold up the bracket (item 7) of the component table.
Æ Lock the two horizontal tensioners (item 11).
Æ Close the side screens and protective cover.
Æ Press the Start button to start the placement system.
4
4
User Manual SIPLACE S-25 HM 4 Component handling
Software Version SR.503.xx 04/2002 US Edition 4.7 Matrix tray changer
151
4.7 Matrix tray changer
4.7.1 Overview
Fig. 4.7 - 1 Matrix tray changer, back view
(1) Main switch
(2) Emergency stop mushroom-head push-button
(3) Tower 1 for up to 40 waffle trays
(4) Tower 2 for up to 40 waffle trays
(5) Feed axis 1
(6) Feed axis 2