1 Introduction, technical data User Manual SIPLACE S -25 HM 1.8 Technical data – ratings Software Version SR.503.xx 04/2002 US Edition 26 1.8 T echnical dat a – r atings 1.8.1 T echnical dat a – elec trical ra tings 1 1.…

User Manual SIPLACE S-25 HM 1 Introduction, technical data
Software Version SR.503.xx 04/2002 US Edition 1.7 Electrical and pneumatic connection points
25
DANGER
The placement system is supplied with 3 x 400 V or 3 x 208 V (US version) ± 5%, 50/60 Hz main
power voltage. This means that some parts of the system carry potentially lethal voltages - even
when switched off at the main switch. Incorrect handling of the placement system can therefore
result in death or severe injury or considerable damage to equipment. 1
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury. 1

1 Introduction, technical data User Manual SIPLACE S-25 HM
1.8 Technical data – ratings Software Version SR.503.xx 04/2002 US Edition
26
1.8 Technical data – ratings
1.8.1 Technical data – electrical ratings
1
1.8.2 Technical data – compressed air supply
1
1.8.3 Technical data – compressed air specification
Maximum particle size by density, based on ISO/DIS 8573-1 (class 1) 1
1.8.4 Technical data – noise emissions
1
1
1.8.5 Technical data – permissible ambient factors
1
Supply voltage 3 x 400 VAC ± 5 %; 50/60 Hz (Europe)
3 x 208 VAC ± 5 %; 50/60 Hz (U.S.A.)
3 x 200 VAC ± 5 %; 50/60 Hz (Japan)
Fuses 3 x 16 A (3 x 400 VAC, 3 x 208 VAC, 3 x 200 VAC)
Total connected load 5 kVA
Total power 2 kW
Power failure up to 20 msec
Compressed air pressure Min. 5.5 bar, max. 8 bar, 1/2" connecton
Compressed air consumption 400 Nl/min.
Operating pressure 5.2 bar (fixed)
Particle size 0.1 µm
Particle density 0.1 mg/m³
Maximum oil content (class 1) Particle density 0.01 mg/m³
Pressure dewpoint (class 4) Dewpoint +3°
Max. noise emission 74dB(A)
Room temperature Between 15°C and 35°C
Atmospheric humidity 30 to 80%
(but no higher than 45% on average in order to prevent
any possibility of condensation on the machine).

User Manual SIPLACE S-25 HM 1 Introduction, technical data
Software Version SR.503.xx 04/2002 US Edition 1.9 Dimensions and weight of the placement system
27
1.9 Dimensions and weight of the placement system
1.9.1 Dimensions of the placement system
1
Fig. 1.9 - 1 Dimensions of the placement system in millimeters
1.9.2 Technical data - dimensions, weight
1
Length 1587 mm including conveyor belts
Width 2793 mm including brackets
Height with warning lamp 1836 mm (standard height) / 1916 mm / 1936 mm/
1956 mm SMEMA
Ground clearance 120 mm standard height
Weight of basic module 1500 kg
Weight fully equipped approx. 2000 kg
Admissible load per unit area on foundation 1000 kg/m² min.
Load per unit area on mounting feet 4.42 kg/cm²