ACT - Accuracy Check Tool mit SSW 6xx User Manual 2017 - 第108页

ACT with SSW 6xx / User Manual 07/2017 Edition 44 4.2.2 Setting Up Components in a WPC/MTC ► Move the tray changer i nto the refill posit ion. ► Remove an empt y plate (waffle pack tray carrier) f rom the tower. ► Fasten…

100%1 / 132
ACT with SSW 6xx / User Manual 07/2017 Edition
43
Figure 4-15: Intervention guard completely mounted
Figure 4-16: Tray set up with intervention guard
NOTICE
The gaps still remaining to the left and right of the tray must be closed off with the
dummy feeders described above so that full protection against intervention in the
machine from the outside is ensured.
ACT with SSW 6xx / User Manual 07/2017 Edition
44
4.2.2 Setting Up Components in a WPC/MTC
Move the tray changer into the refill position.
Remove an empty plate (waffle pack tray carrier) from the tower.
Fasten the tray on the plate as displayed below.
Push the plate into the corresponding level according to the specified setup.
Figure 4-17: Fastening tray on plate
NOTICE
The tray has a cutout at the bottom of the long side.
Therefore, use the magnets for fastening the tray so that the high plate side of the
magnet faces the tray and not the rubber side.
ACT with SSW 6xx / User Manual 07/2017 Edition
45
4.2.3 Inserting the Plate
Insert the glass plate with the incident light plate (black metal plate) underneath it in the input
section.
NOTICE
The measuring plate needs to be inserted so that the arrows marked on the plate show
in the transport direction.
Figure 4-18: Placing the measuring plate in the conveyor (example SIPLACE X4)
NOTICE
Check the orientation of the inserted plate if you see the following error message
(ACT cross cannot be measured).
Figure 4-19: Error message caused by faultily inserted plate