HS50_advance_level 2 - 第242页

07/2002 Editio n Student G uide HS -50 Advanc ed II 8 Y-Axis 24  0HFKDQL FDOVH WWLQJV  3UR[LPLW\ 6ZLWFK< $ [LV NOTE The distance b etween b oth prox imity s witches o f the x - and y- ax is, is set to 0.2…

100%1 / 431
Student Guide HS-50 Advanced II 07/2002 Edition
8 Y-Axis
23
CAUTION Make sure that the cables are firmly seated. Otherwise, the high acceleration
forces may cause the cable to slip out of position and shear through.
Fit the permanent magnets (4 or 16 M6 x 12 hexagon socket-head screws).
CAUTION Settings for the permanent magnetsn (see Fig. 8.5 - 4 ).
Place two 1 mm thick feeler gauges beneath the magnetic plate so that the holes line up ex-
actly with the screw.
Before you attach the magnetic plate, place a 0.8 mm thick non-magnetic spacer (e.g. incre-
mental encoder film) between the magnetic plates, otherwise they will be attracted to one an-
other and will be difficult to separate.
Fit the black cover strips on the cross-beam above the gantry concerned (3 M6 x 8 hexagon
socket-head screws).
 6HWWLQJV
Use the belt tension measuring device to set the X-axis toothed belt tension to 53 Hz + 1/-3 Hz.
CAUTION Do not overstretch the toothed belt when adjusting the belt tension.
Secure the hexagon socket-head screw.
07/2002 Edition Student Guide HS-50 Advanced II
8 Y-Axis
24
 0HFKDQLFDOVHWWLQJV
 3UR[LPLW\6ZLWFK<$[LV
NOTE
The distance between both proximity switches of the x- and y- axis, is set to 0.2 mm.
(Measured from the operational plane).
Student Guide HS-50 Advanced II 07/2002 Edition
8 Y-Axis
25
 -XPSHU6HWWLQJV*DQWU\'LVWULEXWRU6