Stud ent Gu ide HS-5 0 Adva nced II 07/2 002 Ed ition 9 Z-Axis 31 .(< (1) LED: Re ady for o peration (2) LED: E nable output stage (3) LED: I RMS limi t (4) LED: Error MP1 = Nom inal curren t "I-S ( U)"…

07/2002 Edition Student Guide HS-50 Advanced II
9 Z-Axis
30
$[LVG\QDPLFV
NOTE: All SITEST functions are explained by the use of gantry 1
7RROVDQG7HVW$LGV
– 2 or 4 channel storage oscilloscope, SIPLACE axis test box, SITEST software.
NOTe: The machine must have reached its operating temperature before you begin to adjust
the axes.Therefore, make sure to switch it on, at least 30 minutes before you begin to work.
6HUYR%RDUG+HDG$[HV+6
TDS 120 A2.5Z = Servo board z-axis
TDS 120 / 1D = Servo board dp - axis
TDS 120 = Pin configuration
LED: Ready for operation
LED: Enable output stage
LED: Effective current limit
LED: Error
Potentiometer: Tacho
Potentiometer: P-Amplification
Ns Speed setpoint value
Ie Setpoint value, power input
Ta Tacho (real tacho voltage)
Is Nominal current (speed controller output)
IA Motor manipulated variable (speed con troller output)
li Actual current
Ss Sensor stop signal
0V Amplifier electronic GND

Student Guide HS-50 Advanced II 07/2002 Edition
9 Z-Axis
31
.(<
(1) LED: Ready for operation
(2) LED: Enable output stage
(3) LED: I
RMS
limit
(4) LED: Error
MP1 = Nominal current "I-S (U)"
MP2 = Nominal current "I-S (W)"
MP3 = Actual current "I-ist (U)"
MP4 = Actual current "I-ist (W)"
MP5 = "U-nominal (U)"
MP6 = "U-nominal (W)"
MP7 = Free
MP8 = Reference potential "0V"

07/2002 Edition Student Guide HS-50 Advanced II
9 Z-Axis
32
2YHUYLHZRI$[HV&RQWURO&DUGV+6
type of axis and gantry number
adress of axis
'3 '3
'3
'3
CE = Counting error
0 = Zero pulse
ED = End signal
BE = General error, module error
IN = Initialized
ON = Servo ON
(A) Axis enable switch
(1) Servo ON
(2) Servo OFF