HS50_advance_level 2.pdf - 第328页

07/2002 Editio n Student G uide HS -50 Advanc ed II 11 DP-Axis 6   5 HSO DFLQJ VS DUHS DUW V   5HSODF LQJWKHWXUQLQJ VW DWL RQ     7 RROVDQGHTXLSPHQW – Set of DIN 91 1 Allen keys – S…

100%1 / 431
Student Guide HS-50 Advanced II 07/2002 Edition
11 DP-Axis
5
 '3$[LV
 3DUWVRYHUYLHZ

,WHPLQ)LJ 'HVLJQDWLRQ ,WHPQR
1 Forced air unit / DLM1 00335984-01
2 Silencer 00320964-01
3 Turning station / DLM1 00341780-01
424
x24 component camera KST 00336791-02
07/2002 Edition Student Guide HS-50 Advanced II
11 DP-Axis
6
 5HSODFLQJVSDUHSDUWV
 5HSODFLQJWKHWXUQLQJVWDWLRQ
 7RROVDQGHTXLSPHQW
– Set of DIN 911 Allen keys
– SITEST program
 3DUWV
Turning station / DLM1, item no. 00341780-01 
 'LVPDQWOLQJWKHWXUQLQJVWDWLRQ
➠ Switch the placement system off and secure it to prevent switching on.
➠ Remove the plugs from sockets X12 and X18 on the head board.
➠ Push the collect&place head until it reaches the stopper on the deflection roller of the X-axis
toothed belt.
➠ Undo the M3x25 hexagon socket-head screw (see item 2 in Fig. 11.2 - 2) on the rear panel of
the back part.
➠ Carefully pull the turning station (item 1 in Fig. 11.2 - 2) back and remove.
Student Guide HS-50 Advanced II 07/2002 Edition
11 DP-Axis
7
(1) Turning station / DLM1
(2) M3x25 hexagon socket-head screw
(3) Back part of the collect&place head
 )LWWLQJWKHWXUQLQJVWDWLRQ
➠ Make sure that the contact surfaces of the turning station and rear panel are clean.
➠ Insert the M3 x 25 hexagon socket-head screw (item 2 in Fig. 11.2 - 1) into the hole in the
centering station.
➠ Run the cable between the vacuum hose and the vacuum generation socket.
➠ Place the holes in the turning station on the parallel pins.
➠ Carefully push the turning station towards the back part until it reaches the stop.
➠ Fix the turning station with the hexagon socket-head screw.
➠ Plug the cable into sockets X12 and X18 on the head board (see item X12 and X18 in Fig.
11.2 - 1
, page 11 - 6.
 6HWWLQJV
➠ Switch the placement system on and start it up.
➠ Use the SITEST program to run a function test.