47
Loosen the clamping screws (1). Pull the terminal wires out one by one and identify with adhe-
sive labels.
Press down on the lug (2) on the back of the circuit-breaker (3).
Tilt the circuit-breaker (3) upwards slightly and remove.
 )LWWLQJFLUFXLWEUHDNHU0606
Set the thermal overload current on the dial (1) to 0.45 A.
Place the circuit-breaker (2) on the top-hat rail and snap into place.
Connect up the terminal wires.
Switch the placement system on and start it up.
Use the digital voltmeter to measure the 3 x 230 VAC supply at input terminals 1, 3, 5 and out-
put terminals 2, 4 and 6.
Complete the servicing work as described in 3.3.3 on page 3 - 29.
07/2002 Edition Student Guide HS-50 Advanced II
3 Power Supply
48
 5HSODFLQJWKHFRPELQHGFRQWDFWRUSURWHFWLYHGHYLFH66.
 7RROVDQGHTXLSPHQW
Set of slotted-head screwdrivers
Self-adhesive labels
Digital multimeter
HS-50 detailed circuit diagrams
 3DUWV
3TK2805/24 VDC/5S-1NC combined contactor/protective device, item number 00341222-01
 5HPRYLQJWKHFRPELQHGFRQWDFWRUSURWHFWLYHGHYLFH
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
49
Loosen the clamping screws (1). Pull the terminal wires out one by one and identify with adhe-
sive labels.
Use the screwdriver to press down on the locking lug (2) on the back of the combined contac-
tor/protective device (3).
Tilt the combined contactor/protective device upwards slightly and remove.
 )LWWLQJWKHFRPELQHGFRQWDFWRUSURWHFWLYHGHYLFH
Place the combined contactor/protective device on the top-hat rail and snap into place.
Connect up the terminal wires.
Switch the placement system on and start it up.
Use the digital voltmeter to measure the voltages at the terminals as per circuit diagram
00336145-XXXXXX-LD4.
Complete the servicing work as described in 3.3.3 on page 3 - 29.
 5HSODFLQJWUDQVIRUPHU7
 7RROVDQGHTXLSPHQW
Set of slotted-head screwdrivers
Open-ended spanner, size 13
DIN 911 Allen key, size 6
Self-adhesive labels
–Fork-lift truck
Tripod with block and tackle for lifting the transformer
Digital multimeter
HS-50 detailed circuit diagrams
 3DUWV
11.1 kVA transformer, item number 00345634-01
 5HPRYLQJWUDQVIRUPHU7
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).