HS50_advance_level 2 - 第90页

07/2002 Editio n Student G uide HS -50 Advanc ed II 3 Power Sup ply 52    )L WWLQ JWKH WUD QVIR UPH U7 ➠ Check tha t there are four rubber washer s and fou r plain washers on the sc rew bolts on the bot- tom…

100%1 / 431
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
51
Loosen the M8 hexagon nuts (item 3 in the Fig. 3.3 - 20 and 3.3 - 21).
Remove the four plain washers (4) and four rubber washers (5) (see Figs. 3.3 - 20 and 3.3 -
21).
Lift the transformer out of the unit.
WARNING The transformer is very heavy so it should either be lifted by two
people or by one person using a tripod with block and tackle.
07/2002 Edition Student Guide HS-50 Advanced II
3 Power Supply
52
 )LWWLQJWKHWUDQVIRUPHU7
Check that there are four rubber washers and four plain washers on the screw bolts on the bot-
tom of the unit.
Place the transformer in the power supply unit.
Place the four rubber washers (5) on the screw bolts.
PLEASE NOTE:
These rubber washers are important because they absorb noise and vibration.
Attach the four plain washers (4).
Use the four M8 hexagon nuts to fix the transformer T1 in place.
Connect the terminal wires to the primary and secondary terminals.
Switch the placement system on and use the digital voltmeter to measure the voltages on the
primary and secondary sides of the transformer (see Fig. 3.2 - 4
and 3.2 - 5 on page 3 - 18.
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
Push the power supply unit so that it is half-way in the placement system.
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
53
CAUTION
Ensure that the cables do not become trapped, otherwise the insulation will be damaged.
Fix the fixing bar in place.
Complete the servicing work as described in 3.3.3 on page 3 - 29.
 5HSODFLQJUHFWLILHU9DQG9
 7RROVDQGHTXLSPHQW
Set of slotted-head screwdrivers
Open-ended spanner or socket spanner, size 8
Self-adhesive labels
Heat transfer compound
Digital multimeter
HS-50 detailed circuit diagrams
 3DUWV
V1, V7 rectifier S101-B6U-160-08, item number 00341246-01
 5HPRYLQJWKHUHFWLILHU
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).