07/2002 Editio n Student G uide HS -50 Advanc ed II 3 Power Sup ply 56  ➠ Detach the c able lug s (1) fr om the ter minal li nks one b y one a nd ide ntify the te rmin al wires with self-ad hesiv e lab els. ➠ Loosen the…

100%1 / 431
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
55
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
Fix the perspex panel to the rectifier.
PLEASE NOTE:
Do not overtighten the M5 fillister head screws, otherwise the panel might break.
Complete the servicing work as described in 3.3.3 on page 3 - 29.
 5HSODFLQJUHFWLILHU99999RU9
 7RROVDQGHTXLSPHQW
Open-ended spanner or socket spanner, size 10
–Pliers
Self-adhesive labels
Heat transfer compound
Digital multimeter
HS-50 detailed circuit diagrams
 3DUWV
 5HPRYLQJUHFWLILHU9WR9DQG9
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
3RVLWLRQ 'HVLJQDWLRQ ,WHPQXPEHU
V2 Rectifier S61-B2U 28-02 00341244-01
V3 - V6, V8 Rectifier S63-B6U 28-02 00341245-01
07/2002 Edition Student Guide HS-50 Advanced II
3 Power Supply
56
Detach the cable lugs (1) from the terminal links one by one and identify the terminal wires with
self-adhesive labels.
Loosen the M6 hexagon head screw (2) and remove the retaining ring (3).
Remove the rectifier (4).
Remove residue of heat transfer compound from the surfaces of the unit.
 )LWWLQJUHFWLILHU9WR9DQG9
Apply heat transfer compound to the "metal side" of the rectifier.
Fit the rectifier (4) and retaining ring (3).
Fix the rectifier in place with the M6 hexagon head screw (2).
Attach the cable lugs, ensuring that the polarity is correct.
Switch the placement system on and start it up.
Measure the voltages as per the table "Voltages at rectifiers V1 - V8" on page 3 - 16.
Complete the servicing work as described in 3.3.3 on page 3 - 29.
 5HPRYLQJHOHFWURQLFORDGGLVFRQQHFWLQJUHOD\(/5RU(/5
 7RROVDQGHTXLSPHQW
Set of slotted-head screwdrivers
Digital multimeter
HS-50 detailed circuit diagrams
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
57
 3DUWV
 5HPRYLQJ(/5RU(/5
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
Use the screwdriver to push back the yellow (1) terminal link slightly.
Pull the terminal wires out one by one and identify with adhesive labels.
Use the screwdriver to press down the two locking lugs (2) on the back and remove ELR1 (3)
or ELR2 from the top-hat rail.
 )LWWLQJ(/5RU(/5
Place ERL1 and/or ERL2 on the top-hat rail and snap into place.
Check that it is firmly seated.
Connect the marked terminal wires. Ensure that they are firmly attached.
3RVLWLRQ 'HVLJQDWLRQ ,WHPQXPEHU
ELR1, ELR2 (Fig. 5.8.2) Board ARL TC 31034-01 00341835-01