HS50_advance_level 2 - 第98页

07/2002 Editio n Student G uide HS -50 Advanc ed II 3 Power Sup ply 60  3D UW V   5HPRY LQJPDL QSRZHU ILO WHU= DANGER Switch off the place ment syste m and d isconne ct from the po wer supply ( see s…

100%1 / 431
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
59
Loosen the screws (1) and identify the polarity of the terminal wires with adhesive labels.
Loosen the Phillips screw (2) and lift the capacitor (3) out of the clamping ring (4).
 )LWWLQJWKHHOHFWURO\WLFFDSDFLWRU
Fit the capacitor and clamp in place.
Ensure that the polarity is correct when you connect the terminal wires.
Switch the placement system on.
Use the digital voltmeter to measure 52 VDC at the capacitor.
Complete the servicing work as described in 3.3.3 on page 3 - 29.
 5HSODFLQJPDLQSRZHUILOWHU=
 7RROVDQGHTXLSPHQW
Set of slotted-head screwdrivers
Open-ended spanner, size 8 and socket spanner, size 10
Self-adhesive labels
07/2002 Edition Student Guide HS-50 Advanced II
3 Power Supply
60
 3DUWV
 5HPRYLQJPDLQSRZHUILOWHU=
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
Loosen the clamping screws (1) for the terminal wires one by one and identify the terminal
wires with adhesive labels.
Loosen the M6 hexagon nut (2) and pull out the protective earth cable.
Loosen the M5 hexagon nuts (3) for fixing the main power filter.
Remove the main power filter (4).
 )LWWLQJWKHPDLQSRZHUILOWHU=
Fit the main power filter (4) and fix in place with the M5 hexagon nuts (3).
Attach the terminal wires (1).
Attach the protective earth cable (2).
3RVLWLRQ 'HVLJQDWLRQ ,WHPQXPEHU
Z1 Main power filter for 36 A 3-phase systems 00342397-01
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
61
Connect the placement system to the power supply.
Measure the voltages at the main power filter’s input and output:
3 x 204 VAC / 3 x 230 VAC / 3 x 380 VAC / 3 x 400 VAC / 3 x 415 VAC
Complete the servicing work as described in 3.3.3 on page 3 - 29.
 5HSODFLQJWKHLQUXVKFXUUHQWOLPLWDWLRQERDUG(67
 7RROVDQGHTXLSPHQW
Set of slotted-head screwdrivers
Open-ended spanner or socket spanner, size 8
Self-adhesive labels
Digital voltmeter
 3DUWV
 5HPRYLQJWKH(67ERDUG
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
3RVLWLRQ 'HVLJQDWLRQ ,WHPQXPEHU
EST Inrush current limitation board TG 31033-01 00341831-01