TM3808.Setting of scanning procedure during a splicing - 第4页

 SMT Software Engineering Group  IM Operati ons Y AMAHA MOTOR CO., L TD   MDOC- SOFT50149  4/9 3.2 Modifica tion method of scan procedure Make a s etting with "Syste m Config" on PC with Y AMA HA IT -Sys…

100%1 / 9
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD
MDOC-SOFT50149
3/9
3 Setting
3.1 Recommended setting
The initial value after the upgrade is the following. This is an existing procedure.
Setting Item Initial value
Splicing Process Barcode Label Use (Scan possible)
Splicing Old Parts Scan Procedure Either (Old Parts/Feeder)
Recommended setting in each operation form is as follows.
- When reel ID (stick ID/bulk ID) is used
Setting Item Setting value
Splicing Process Barcode Label Not Use
Splicing Old Parts Scan Procedure Only Old Parts
It is necessary to scan ID of old parts to specify the splicing ahead.
(Feeder ID scanning is unnecessary.)
- When reel ID (stick ID/bulk ID) is unused
Setting Item Setting value
Splicing Process Barcode Label Use (Scan necessary)
Splicing Old Parts Scan Procedure Both necessary (Old Parts/Feeder)
It is necessary to scan old parts and feeder ID to specify the splicing ahead.
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD
MDOC-SOFT50149
4/9
3.2 Modification method of scan procedure
Make a setting with "System Config" on PC with YAMAHA IT-System installed.
1. Start "System Config" from [Start] - [Program] - [YAMAHA IT-System] - [System Config]
2. Click the [Change] button to make amodifiablestate.
3. Select [Inline Setup] from the [Setting Item] combo box.
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD
MDOC-SOFT50149
5/9
4. Select [All Lines common] - [OP002] - [The Other Procedure] from the tree view and
perform [Splicing Process Barcode Label] setting.
-Setting Item
Setting Item Initial value
Content
Splicing Process
Barcode Label
Use (Scan
possible)
Whether the “Process barcode label” is scanned is set as
beginning of the splicing work.
Use (Scan possible): *Current scanning procedure
Scanning “Process barcode label”, splicing starts.
If you don’t scan “Process barcode label”, it
is also possible
to start splicing.
Use (Scan necessary):
The splicing can’t start without scanning “Process barcode
label”.
Not Use:
Select this if you don’t use “Process barcode label”.
Splicing doesn’t start even when “Process barcode label”
(splicing) is scanned.
5. Select “Common” from the [Setting Item] combo box.