00197089-02_AI_EA-Verl_X-Serie_S_de_en - 第44页

Introduction Safety Instructions 1.1.2 Safety In structions for Working with S trong Magnetic Fie lds 44 Extension Input/Output Conveyor and Hand Guard Ein-/ 1.1.2 1 . 1 . 2 S a f e t y I n s t r u c t io n s f o r W o r…

100%1 / 80
Introduction
1.1.1 Conventions for the use of safety instructions Safety Instructions
Extension Input/Output Conveyor and Hand Guard Ein-/Ausgabebandverlängerung und Eingreifschutz 43
1
1 Introduction
Introduction
This manual describes installation of the "Input and Output Conveyor Extension incl. Hand Guard" in the
SIPLACE® X series S machines.
1.1
1.1 Safety Instructions
Safety Instructions
1.1.1
1.1.1 Conventions for the use of safety instructions
Conventions for the use of safety instructions
This manual contains notes that must be observed to guarantee your personal safety and to avoid dam-
age to equipment. These notes are highlighted by warning triangles and are indicated as follows accord-
ing to the level of risk:
DANGER
Nonobservance of these safety instructions may cause injury to personnel and damage to the
machine!
Please observe the safety instructions in the user manual of the relevant machine for all
work!
DANGER
Definition
For the purposes of this manual, this indicates that fatal or severe injuries or considerable dam-
age to property will occur if this hazard warning is not observed.
WARNING
Definition
For the purposes of this manual, this indicates that fatal or severe injuries or considerable dam-
age to equipment may occur if these warning instructions are not followed.
CAUTION
Definition
For the purposes of this manual, this indicates that minor injuries or damage to property may
occur if this caution is not observed.
NOTICE
Definition
For the purposes of this manual, this note provides information about the product or indicates
a part of the manual that requires particular attention.
Introduction
Safety Instructions 1.1.2 Safety Instructions for Working with Strong Magnetic Fields
44 Extension Input/Output Conveyor and Hand Guard Ein-/
1.1.2
1.1.2 Safety Instructions for Working with Strong Magnetic Fields
Safety Instructions for Working with Strong Magnetic Fields
1.1.3
1.1.3 Safety Instructions for the Power Supply
Safety Instructions for the Power Supply
This means that some parts of the system carry potentially lethal voltages - even when switched off
at the main power switch.
Incorrect handling of the placement system can therefore result in fatal injuries, severe injuries or
considerable damage to equipment.
Measurements and maintenance work must always be carried out by appropriately qualified person-
nel.
Always follow the applicable accident prevention and DIN regulations (particularly DIN EN 60 204,
part 1) or the regulations specific to your country.
Before starting any maintenance work, switch the machine off at the main switch and disconnect it
from the main power supply.
Always secure the machine against unauthorized reactivation. If these instructions are not followed,
you may be able to touch live parts, which could result in fatal or severe injuries.
Maintaining or Replacing Assemblies
End all placement operations on the machine.
Shut down the Windows operating system correctly, otherwise problems may occur when restarting
or data may be lost.
Switch the machine off at the main switch.
Disconnect the machine from the main power supply.
Switch off the machine and attach warnings signs to indicate that service work is in progress.
DANGER
Strong permanent magnet fields
Fatal hazard: persons with active implants (e.g. pacemakers, defibrillators, insulin pumps etc.)
are at risk from strong permanent magnetic fields inside the machine.
Persons at risk should avoid the immediate vicinity of the machine.
CAUTION
Danger of crushing
Danger of crushing for persons with passive metal implants (e.g. plates, screws).
Do not reach or lean over into the machine when the protective covers are open.
Do not bring any metal objects into the hazard area.
CAUTION
Strong permanent magnet fields
There is a risk that the strong magnetic fields could corrupt data on data media or check cards.
Keep sensitive data supports away from the permanent magnets.
WARNING
Hazardous Voltages!
The machine is supplied with 3 x 400 V~ (or. 3 x 204 V~ / 3 x 220 V~ / 3 x 230 V~ / 3 x 380 V~
/ 3 x 415 V~) ± 5 %, 50/60 Hz mains voltages.
Observe the safety instructions in the user manual during all service work!
Introduction
1.1.4 Safety Instructions for the Gantry Safety Instructions
Extension Input/Output Conveyor and Hand Guard Ein-/Ausgabebandverlängerung und Eingreifschutz 45
1.1.4
1.1.4 Safety Instructions for the Gantry
Safety Instructions for the Gantry
1.1.5
1.1.5 Safety Instructions on Hazardous Materials
Safety Instructions on Hazardous Materials
CAUTION
Moving the gantry can damage the placement head.
When moving the gantry, observe the following:
NEVER move the gantry by pushing with your hands against the placement head.
NEVER push the gantry while the Z axis is lowered.
CAUTION
Observe the safety data sheets
Observe the applicable safety data sheet, when handling hazardous materials (e. g. Loctite
241, ethanol).