ASM_MANUAL_TYPHOON_USC_en_100620_online.PDFA - 第18页
3 TYPHOON UNDER STENCIL CLEANER 3.2 USC ASSEMBLIES 18 STANDALONE MANUAL TYPHOON UNDER STENCIL CLEANER 06/2020 3.2.4.1 Hard Top Insert The hard top insert works well for standard cleaning or stencils/paste mediums that re…

3 TYPHOON UNDER STENCIL CLEANER
3.2 USC ASSEMBLIES
STANDALONE MANUAL TYPHOON UNDER STENCIL CLEANER 06/2020 17
There are three types of plenum insert available:
●
Hard Top
●
Poly Blade
●
Duo
6
7
A
9
7
6
B
67
8
5
C
2
3
4
1
1 Solvent Pump to Spray Bar
Connector
7 Spray Bar Solvent Hole(s)
2 Solvent Distribution
(Elbow + Tee)
8 Dry Clean Surface
3 View on underneath of Insert 9 Poly Blade (Squeegee) (2 off)
4 Solvent Distribution (Elbow)
(2 off)
A Hard Top Insert
5 Seep Resistant Slot B Poly Blade Insert
6 Vac Holes C Duo Insert
The following table details the cleaning modes that can be programmed as "single sweep" cleans.
Up to six "single sweep" cleans is the maximum that can be programmed to run between print
cycles.
Plenum Insert Type Solvent Vacuum Clean Mode
Hard Top / Poly Blade / Duo Y N WET
N N DRY
N Y VAC
Duo ONLY Y Y WET/VAC

3 TYPHOON UNDER STENCIL CLEANER
3.2 USC ASSEMBLIES
18 STANDALONE MANUAL TYPHOON UNDER STENCIL CLEANER 06/2020
3.2.4.1 Hard Top Insert
The hard top insert works well for standard cleaning or stencils/paste mediums that require high
vacuum to aid excess paste removal.
3.2.4.2 Poly Blade Insert
The poly blade insert works well with stencils with irregular undersides (worn stencils, coined sten-
cils, stepped stencils etc).
3.2.4.3 Duo Insert
The duo insert is capable of performing a WET and VAC clean in one sweep, an option which uses
less fabric roll and has less of an impact on machine throughput.
3.2.5 Solvent Pump and Supply
The solvent pump mounted on the right-hand USC cleaner support bracket, supplies solvent to the
plenum chamber mounted solvent spray bar which can then be applied to the fabric roll. The
solvent tubing from the pump is fitted with a quick release connector, which makes the removal of
the plenum chamber for maintenance etc much simpler.
The pump provides solvent from the external solvent tank mounted on the rear or either side of the
machine. The external solvent tank is capable of accommodating a 5 litre container of solvent. A
load cell in the base of the external solvent tank enables the software to calculate the percentage
level of solvent within the container.
2
3
1
1 Solvent Tubing from External
Solvent Tank
3 Solvent Pump
2 Solvent Tubing from Pump
3.2.6 Vacuum Filtration
The vacuum filtration unit extracts solvent fumes and draws excess print material onto the fabric.
The machine mounted vacuum filtration unit connects to the USC plenum chamber via a vacuum
tube assembly. Vacuum filtration is optional and may be one of the following types:
●
VF35 Vacuum Filtration Unit
●
VF25 Vacuum Filtration Unit
●
VF10 Venturi Vacuum Filtration Unit
NOTE
For information on the removal and replacement of the filters, refer to the Machine Preventive
Maintenance manual.

3 TYPHOON UNDER STENCIL CLEANER
3.2 USC ASSEMBLIES
STANDALONE MANUAL TYPHOON UNDER STENCIL CLEANER 06/2020 19
5
4
3
1
2
1 Stencil Cleaner Connection 4 Telescopic Tube
2 Machine Mount 5 Stencil Cleaner Mount
3 Vacuum Filtration Unit
Connection
3.2.6.1 VF35 Vacuum Filtration Unit
The onboard VF35 vacuum filtration unit is protected by two circuit breakers on the front panel of
the base unit: either a 15A (for 115V) or an 8A (for 230V) which can be reset by pressing the circuit
breaker button covered by a clear plastic protector. For safety, the voltage selector control knob is
removed from the switch and bolted to the fan housing. The VF35i vacuum filtration unit has a
three position mechanical air flow adjuster to regulate the air flow as follows:
●
Maximum (full air flow)
●
Medium (half air flow approximately)
●
Minimum (15% of full air flow approximately)
3.2.6.2 VF25 Vacuum Filtration Unit
The onboard VF25 vacuum filtration unit is protected by either a 10A (for 115V units) or 5A (for
230V units) circuit breaker.
3.2.6.3 VF10 Vacuum Filtration Unit
The onboard VF10 Venturi vacuum filtration unit, located in the front of the machine frame, uses
compressed air to create a vacuum.