00197963-01_AI_Power_Supply_Conversion_SIPLACE_E_en
Titl e SIPLACE E Power Supply Conversion Assembly Instructions Edition 02/2015 EN

Titl
e
SIPLACE E
Power Supply Conversion
Assembly Instructions
Edition 02/2015 EN

All names identified by ® are registered trademarks of ASM Assembly Systems Singapore Pte ltd. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
We have reviewed t he contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be
precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary
connections are included in subsequent editions.
Copyright © ASM Assembly Systems Technical data subject to change
ASM Assembly Systems Singapore Pte ltd
2 Corporation Road
#01-03 Corporation Place
Singapore 618494
Item no.: 00197963-01
www.e-by-siplace.com Printed by ASM Assembly Systems
Table of Contents
Assembly Instructions SIPLACE E 3
Table of Contents
1 Introduction 5
1.1 Safety Instructions 5
1.1.1 Conventions for the use of safety instructions 5
1.1.2 Safety Instructions for Working with Strong Magnetic Fields6
1.1.3 Safety Instructions for the Compressed Air Supply 6
1.1.4 Safety Instructions for the Power Supply 7
1.1.5 Safety Instructions on Hazardous Materials 7
1.2 Preparatory Work... 8
1.3 Other Instructions 10
1.3.1 Environmentally-Friendly Disposal of Materials and Components 10
1.3.2 Use of Original SIPLACE Accessories and Spare Parts 10
1.3.3 ESD Guidelines 10
1.3.3.1 Definition of ESD 10
1.3.3.2 Important Measures to Protect Against Static Charging 10
1.3.3.3 Handling ESD Modules 10
1.3.3.4 Measurements and Modifications to ESD Modules 11
1.3.3.5 Dispatching ESD Modules 11
1.3.4 Validity of Document 11
1.3.5 Release History 11
1.3.6 SIPLACE on the World Wide Web (WWW) 12
1.4 Staff Qualifications and Training 12
2 Brief Description 13
2.1 Scope of Delivery 13
2.2 Tools and Equipment 13
3 Conversion 15
3.1 Preparatory Steps 15
3.2 Circuit Diagrams 16
3.3 Installing the Power Conversion Kit 18
3.3.1 Installing the Cable Harness Assembly 21
3.3.2 Attaching the Voltage Warning Label 23
3.3.3 Configuring the Vacuum Pump and the Overload Relay for US Option 24
3.4 Restoring the Standard Configuration of 3x400V 27
3.4.1 Removing the Power Conversion Kit 27
3.4.2 Removing the Cable Harness Assembly 28
3.4.3 Restoring the Original Vacuum Pump and Overload Relay Configuration 30
3.5 Carrying out Final Safety Checks 32
3.5.1 Safety Check According to DIN EN 60204 32
3.5.2 Vacuum Air Flow Check 32