S27HM Circuit Diagrams - 第53页
2 - 6 NH03-0 10101 LD3 EME RGENCY -STOP circ uit - sign aling circuit wi th po wer sup ply 0037 5539-xx (Jap an v ersion ) Off but ton 00321432 -xx vi 00321432 -xx bk Key-operate d switch 00321434- xx bk 00321434 -xx vi …

2 - 5
NH03-010101LD3 EMERGENCY-STOP circuit with power supply 00375539-xx (Japan version)
33 43 53
66
65
22
K3
21
13
14
K3
44
MP1 M
3RT1015
A2(-)
A1(+)
K2
A2
24614
A1
1
K2
14
13
5313
2
1
T2
43
K3
15
14
T1
bk
bk
24VAC
Fuse F10:2
Sheet 1 5/B
00375539-010101LD3
Sheet 1 5/B
00375539-010101LD3
Sheet 1 6/E
Sheet 1 6/E
bk
Temperature switch
00375539-xx
Power supply
X211/2
00321113-xx
wh
bn
X212:4
whgn
00321113-xx
X211:21
bngn
00321113-xx
00321113-xx
X2ka:6
gybn
X4ka -
00321113-xx
pkbn
X1kb:1
whgy
00321113-xx
X212:11
rd
00321113-xx
X212:4
whye
00321113-xx
X211:22
00321113-xx
yebn
X212:12
pk
00321113-xx
whpk
00321113-xx
X211/17
conveyor
00321432-xx gy
00321528-xx S2
3
00321432-xx pk
push-button
ON
input
4
conveyor
00321434-xx gy
00321113-xx gn
X211/16
00321529-xx S2
3
00321113-xx ye
output
00321434-xx pk
push-button
ON
4
00321113-xx gypk
00321432-xx gn
X211/18
X211/19
00321529-xx S2
00321113-xx rdbl
push-button
conveyor
output
ON
4
00321434-xx ye
00321432-xx ye
00321434-xx gn
3
4
00321528-xx S2
push-button
conveyor
ON
input
3
00321113-xx
bk
00321113-xx
vi
3
00321434-xx whye
Key-operated switch
00321529-xx S4
4
00321574-xx ye
00321574-xx gn
00321573-xx ye
00321573-xx gn
Connecting terminals for feeder crash sensors
jumpers X211/ 25-26, 26-27, 27-28 and 28-29.
WARNING: If you install the option remove
00321416-xx S1
lefthand side
OPTION: X211/ 25,26,27,28,29
00321434-xx bngn
X211/8
21
X211/29
28 2627 25
Protective cover
righthand side
Protective cover
00321417-xx S1
X211/9
22
switch
22
21
switch
00322070-xx bl
X211/15
00321113-xx bl
X211/14
X211/13
00305818-xx ye
00305818-xx gn
00305815-xx ye
00305815-xx gn
X211/11
Protective cover
Output conveyor
00303617-xx S1
22
switch
21
X211/12
Protective cover
Input conveyor
00303614-xx S1
22
21
X211/10
switch
OPTION: Cover switch, succeeding machine (00321421-xx)
Connect cable 00305817-xx to X211/13 gn - X211/14 ye
remove jumper X211/13 - X211/14.
WARNING: If you install the option
Connect cable 00305816-xx to X211/11 gn - X211/12 ye
OPTION: Cover switch, preceding machine (00321421-xx)
remove jumper X211/11 - X211/12.
WARNING: If you install the option
00322069-xx bn
00322111-xx ye
Component table,
lefthand side
00322069-xx bl
00322111-xx gn
lefthand side
MTC interface,
X211/5
1a 00322063-xx/X3ta
2c 00322063-xx/X3ta
3c 00322104-xx/X57a
4c 00322104-xx/X57a
X211/6
1a 00322064-xx/X37b
righthand side
Component table,
2c 00322064-xx/X37b
00322070-xx bn
00322112-xx ye
00322112-xx gn
MTC interface,
righthand side
X211/7
4c 00322105-xx/X57b
3c 00322105-xx/X57b
X211 terminal strip (I/O distributor)
X212 terminal strip (I/O distributor)
X1kb terminal strip (I/O distributor)
X2ka terminal strip (I/O distributor)
X4ka terminal strip (I/O distributor)
00321436-xx bn
EMERG.-STOP
00321529-xx S1
push-button
push-button
Output conveyor
00321528-xx S1
EMERG.-STOP
Input conveyor
1
2
X211/4
NH03_SH01.DWG
Stromlaufplan/Circuit diagram
SMD Placement System SIPLACE S-27 HM
1
2
EMERGENY-STOP circuit
with power supply
00353088-xx
Note:
00321433-xx bn
00321113-xx wh & bn
00321436-xx wh
00321433-xx wh
X211/3
2
1
X211/2
24V AC
K1:X1
Sh.
Sheet
DateStatus Name Stand. Orig./Repl.f/Replaced by
Author
Check.
Date
Mat. no.:
CAD file:
Modified
1.
1.
1.
30.05.05
30.05.05
30.05.05 Hi
Hi
Hi 30.05.2005
Hi
L&A EA
SIEMENS
NH03-010101LD3
Doc. status
Product status
Function status
00375539-xx (version for Japan)
GND
3TK2805
L2 X2 X4 X6 2414 4434 54
K1
L1 X1 X3 X5 13 23
See page 4-19
See page 4-19
See page 4-19
See page 4-4
See page 3-22

2 - 6
NH03-010101LD3 EMERGENCY-STOP circuit - signaling circuit with power supply 00375539-xx
(Japan version)
Off button
00321432-xx vi
00321432-xx bk
Key-operated switch
00321434-xx bk
00321434-xx vi00321434-xx grpk
rdrd
00321434-xx rd
input conveyor
OFF
output conveyor
OFF
X1ka/6
X210/5
X1ka/5
00321528-xx S3
00321529-xx S3
X210/4
X1ka/4X1ka/2
X210/2
X210/1
00321529-xx S200321528-xx S200321529-xx S100321528-xx S1
On buttonEMERG. STOP
00321433-xx ye 00321436-xx ye 00321433-xx grpk
00321433-xx rd00321436-xx gn00321433-xx gn
ONON
output conveyorinput conveyoroutput conveyor
push-button
input conveyor
push-button
X210/3
00321416-xx S1
00321417-xx S1 00321614-xx S1
14
1313
1414
13
00305818-xx wh
00305818-xx br
Cover protective
switch
output conveyor
00305817-xx br
00305817-xx wh
13
14
00303617-xx S1
13
14
A2 (-)
A1 (+)
33
34
X211/21X211/22
6
5
22
21
X212/4X212/4X212/4
K1
00321113-xx grbn00321113-xx whgn00321113-xx whye00321113-xx whgn
00321113-xx brgn00321113-xx yebr00321113-xx whgr
Software release
Monitoring K2
Control OnControl On
Monitoring K3
Software release
X212 terminal strip (I/O distributor)
X211 terminal strip (I/O distributor)
X210 terminal strip (I/O distributor)
Note:
13
14
Cover protective
lefthand side
switch
Cover protective
00321573-xx br
switch
righthand side
00321573-xx wh 00321574-xx wh
00321574-xx br
Cover protective
input conveyor
switch
preceding
switch
Cover protective
00305815-xx br
00305815-xx wh 00305816-xx wh
00305816-xx br
Cover protective
switch
succeeding
NH03_SH02.DWG
Stromlaufplan/Circuit diagram
SMD Placement System SIPLACE S-27 HM
2
2
EMERENCY-STOP circuit - signaling circuit
with power supply unit
00353088-xx
Signaling circuit Signaling circuit Signaling circuit Signaling circuit
blbk blbk
monitoring of control ON and software release signal
Signaling circuits
Cover switch signaling circuit
EMERG.-STOP signaling circuits, ON/OFF push-buttons, key-operated switches
blbk
Cover open
machine
(Option)
00321421-xx S1 00321421-xx S1
(Option)
machine
Push-button Push-button Push-button
blbk
4
3
4
3
4
3
4
3
2
11
2
blbk blbk
1
2
Key-operated
switch
00321529-xx S4
Push-button
EMERG.-STOP EMERG.-STOP
Sheet
Sh.
EMERGENCY-STOP signaling circuit, MTC
blbk
X1ka/2
00322111-xx pk
X210/2
5c 00322104-xx/X57a
6c 00322104-xx/X57a
5c 00322105-xx/X57b
6c 00322105-xx/X57b
00322111-xx gr
blbk
X210/1
EMERG. STOP
00322112-xx pk
00322112-xx gr
MTC interface,MTC interface,
lefthand side righthand side
DateModifiedStatus Orig./Repl.f/Replaced byName Stand.
Author
Check.
Date
Mat. no.:
CAD file:
1.
1.
1.
30.05.05
30.05.05
30.05.05 Hi
Hi
Hi 30.05.2005
Hi
L&A EA
SIEMENS
NH03-010101LD3
Doc. status
Product status
Function status
X1ka/3
X1ka/1-8 SLIO Port1-Port8 Inputs
X2ka/9-16 SLIO Port9-Port16 Outputs
X1kb/1-8 SLIO Port1-Port8 Inputs
X2kb/9-16 SLIO Port9-Port16 Outputs
X2ka/6
00321113-xx pkbn
X1ka/1X1kb/1 X4ka -
X3ka + (+24VDC) X3ka + (+24VDC) + 24VDC + 24VDC + 24VDC
X3kb+ (+24VDC) X3ka+ (+24VDC)
X3ka + (+24VDC)
00375539-xx (version for Japan)
00375539-xx K3
00375539-xx K3 00375539-xx K2 00375539-xx K1
See page 4-4

2 - 7
X01-010101LD3 X-axis, gantry 1
12
13
A
A
B
B
N
N
+15V
+5V
RI_TL
2525
2222
-15V
-15V
+15V
16
31
16
31
10
19
PGND
+24V
10
19
PGND
+24V
Gantry
00354430-xx (ac)
head distributor S-27
X34aa
1
Control unit
Power supply
00364174-xx
00344771-xx
+24V
00344217-xx
(cable)
+5V
+15V
-15V
9
8
7
6
5
+5V
-15V
+15V
+5V
+24V
6
5
Key
GND
GND
Inom U
AGND
PTC
Tacho
Star point
Star point
AGND
PTC
AGND
Key
Tacho +
Tacho -
13
14
21
22
21
22
X14:1
X14:2
13
14
PTC +
PTC -
J1 J2 Not inserted
bk
analysis
00353715-xx
A29 (ve)
Backplane
Tachometer
SIEMENS
L&A EA
X01.DWG
Stromlaufplan/Circuit diagram
SMD Placement System SIPLACE S-27 HM
1
1
X-axis, gantry 1
X18
2
3
4
X12aa
1
+5V
00354765-xx (aa)
Gantry conversion board
Reference point
End position
X-axis enable
Servo unit
00354475-xx
X1
00322100-xx A15
X2va
6
X35aa
2
00353088-xx
Terminal strip
X1kb
2
(cable)
00344224-xx
wh
I/O distributor
gantry 1
Crash signal
00321557-xx
(cable)
00344206-xx A11 (va)
13,2813,28
+5V
11
12
11
12
X10aa
24
X2ab
24
bl3 bl -
X16ac
1
2
(Cable)
00300609-xx
bn
bk bk
bn
+
A1
End pos. prox.
switch B1
+24V
00354765-xx (aa)
Gantry
X8ab
3
1
wh
bn
(Cable)
00321577-xx
Limit switch 1
X-axis
00321423-xx
End pos. prox. switches
B1, B2
Y-axis
00321425-xx
Limit switch 2
X-axis
00321578-xx
(Cable)
X9ab
X6va
1
2
3
4
X5va
3
3
4
4
1
2
2
1
GND
Tacho
Crash
+15V
X11a
Anti-crash board
Dynamic brake
DBM / 3P - 3
RSE
T
ye/gn
bn
GND
Track B
3
4
2
1
Track A
X-axis incremental shaft encoder
X15ac
6
9
8
7
5
gnwh
bk
rd
bl
wh
bn
ye
pk
gn
Zero pulse
Signal
(Track N)
screen
LED
GND
+5V
LED
00349845-xx
(Cable)
8
9
27
26 Track N
Track N27
26
X3ac
00321554-xx
6
5
2
3
29
30
33
32
X3aa
(Cable)
Track B
Track B29
30
Track A
Track A
33
32
X15aa
10
3
1
wh
bn
Conversion board, large-axis
00354764-xx (ab)
S1 S2
conversion board
X38aa
2
6
1
8
7
(cable)
X10aa
29
30
00321557-xx
29
(cable)
X2ab
wh
00321558-xx
(cable)
00354419
00354473-xx
(cable)
A18 (va) 00353714-xx
X-axis (gantry 1)
8
9
7
6
5
4
1
3
2
bl
bn
ye
gy
rd
pk
gn
wh
1,4,7,17,20
1,4,7,17,20
screen
+5V
L2
+15V
+5V
1,341,34
00321547-xx
(cable)
Anti-crash board
to X11e/6
to X11e/1
X11e
6
1
To plug X34aa
Conversion board
gantry
4
3
2
1
X2sz
X1 plug assignment / servo amplifier
A1 (va)
00344204-xx
TBS 200 / 10x
X1
X-axis servo amplifier
X1va
GND1
00364174-xx
Control unit
Cable 00364131-xx
rd
nom. values
X-axis
109
Axis rear panel, gantry 1 A27 (sz)
Crash
8
GND
Enable3
2
Servo Ready
4
5I²t
6
7
14
12
13
10
11
12
13
11
Backplane
Inom W
9
10
12
GND
13
14
X3va
00344251-xx
(Cable)
X1sz
7
8
5
6
00353718-xx
3
4
1
2
8
9
5
6
2
3
X7sz
X-axis,
axis tracks
GND
X2ve
6
5
2
4
5
3
XR
1
4
3
1
2
XT
Tacho U
Tacho V
Tacho W
Tacho Mp
RSE U
RSE V
RSE W
RSE +5V
RSE GND
U
V
W
M
3~
ye
bn
gn
ye/gn
ye
bk
rd
wh/bk
rd
vi
wh/br
or
(cable W2)
00337065-xx
(cable W1)
00337065-xx
prox. switch 1
End position
prox. switch 1
RSE = Rotary Shaft Encoder
Sh.
Sheet
3,3k
Status DateModified Name Stand. Orig./Repl.f/Replaced by
CAD file:
Mat. no.:
Check.
Date
Author
1.
1.
1.
02.12.02
02.12.02
02.12.02 Hi
Hi
Hi 02.12.2002
Hi
X01-010101LD3
Doc. status
Product status
Function status
X2smX1sm
XC1su
Machine controller M54
backplane
Multi-purpose
A32 (su)
00357328-xx
XC1suXA3su
XB6suXA1su
X1sa
A1 (sa)
X2sa
Axis board (Gantry 1)
A6 (sm)
Axis service
X3sm
00349456-xx
-15V4d
6z
+15V4z
6d Brake +
Brake -
12z
12d
10d
8d
AGND
Servo Ready
Inom U
Inom W
30z,b,d
24z,b,d
Motor V
28z,b,d
26z,b,d
GND
20z,b,d
22z,b,d
18z,b,d
Enable14d
16d
32z,b,d
I²t
+Ub
GND
+Ub
Motor V
Motor W
Motor U
-15V
+15V
GND
0/155V(Ub)
X12:43
X12:184
007
009
2
X7va
1
X14
1
2
X2:21
X2:22
X motor
00337065-xx
S-27
gy
gy
PTC
4
5
3
2
X4va
1
4
5
3
2
X4ve
1
66
Key
AGND
Tacho
PTC
8
7
10
bk
bl
Tacho U
Tacho V
Tacho W
Tacho Mp
RSE V
RSE W
RSE +5V
RSE GND
Motor U
Motor V
Motor W
Power GND
RSE U
3
4
5
10,11,12
X36aa
4
3
1
2
5
32
33
32
31
X37aa
29
30
33
X10aa
X11aa
30
32
33
X12ab
32
31
29
30
33
X2ab
3,6,9,12,15
4,7,10,13,16
2,5,8,11,14
3,6,9,12,15
4,7,10,13,16
X1ab
2,5,8,11,14
(cable)
00337532-xx
00321557-xx
(cable)
U
V
W
X13ab
4
3
2
1
10
8
7
6
5
X3ab
5
4
3
2
1
See page 5-18
See page 3-6
See page 5-33
See page 5-30
See page 5-32
See page 4-5
See page 5-26
See page 5-33
See page 5-5
See page 5-27
See page 2-20
See page 1-30
See page 5-34
See page 5-16