S27HM Circuit Diagrams - 第82页
2 - 35 BT01- 010101LD 3 Compo nent table , mobil e, lefthan d side +5VDC +24VAC +30VDC GND 1 3 2 X1do 5 4 X23dp 2 5 3 4 1 X22dp A17/A18/B17/B18/C17/C18 C32 A15/A16/B14/B15/C14/C15 A19/B18/B19/C18 A1 X2do X21dp 28VAC 8VAC…

2 - 34
BT01-010101LD3 Component table, mobile, righthand side
BT01.DWG
Stromlaufplan/Circuit diagram
Sh.
Sh.
SMD Placement System SIPLACE S-27 HM
1
1
Component table, mobile,
(Cable)
00328753-xx
bn
X37b
3a
2a
X37b
Interface for comp.-handling
GND (5V)
Control unit
00364174-xx
00326142-xx
assembly
Communications
4a
bn
00321429-xx
(Cable)
gn
wh
5
3
2
X3sd
wh
gn
bn
V-24
TxD
RxD
GND
(righthand side)
00322064-xx
righthand side
2a
3aRxD
gn
4aTxD
ye
gr&pk
rd&bk
bl
5a
7a
6a
+5VDC
+30VDC
GND (5V)
rdbl
grpk
vi
3b
2b
1b
C
B
A
whgr
whpk
yebr
whye
brgn
whgn
1c
3c
7b
6b
5b
4b
Y5
GE
GND (30V)
Y7
Y6
brrd&whbk
brbl&whrd
whbl
pkbr
2c
1a
7c
6c
5c
4c
to tape cutter
EMERGENCY-STOP loop
bn
bl
Terminal panel,
00353088-xx
7
25
X211
I/O distributor
bn
bl
(Cable)
00322070-xx
1a
2a
00356643-xx
Terminal panel,
voltages
N
L3
X206
(Cable)
00322068-xx
X36b
PE
gnye gnye
X36b
3
4
PE
gnye
bl
L3 bn
00300379-xx
(Cable)
Control board, component table
X4do
3
4
6
X9do
3
1
2
4
5
5
4
X7do
2
3
1
6
8
7
9
13
14
F1
00323583-xx
GND (5V)
RxD
TxD
bn
ye
gn
pkbr
brrd&whbk
brbl&whrd
whpk
whbl
rdbl
grpk
vi
whgr
rd&bk
gr&pk
whye
yebr
whgn
brgn
bl
n.u.
GND (5V)
GND (30V)
C
B
A
GE
Y5
Y7
Y6
+30VDC
+5VDC
bl
gnye
bn
5
11
4
3
2
1
10
9
7
8
6
28V/3A
8V/2A
0V
8V/2A
28V/3A 1
4
2
3
5
PE
230V
230V
115V
+5%
0V
-5%
gnye
1.5mm²
1.5mm²
gnye
F1 = 3.15 AT at 230VAC
F1 = 6.3 AT at 115VAC
Transformer
to
table crosshead
+5VDC
+24VAC
+30VDC
GND
1
3
2
X1do
5
4
X23dp
2
5
3
4
1
X22dp
A17/A18/B17/B18/C17/C18
C32
A15/A16/B14/B15/C14/C15
A19/B18/B19/C18
A1
X2do
X21dp
28VAC
8VAC
8VAC
0V
28VAC
1
2
3
4
5
00301069-xx
(Cable)
8VAC
28VAC
0V
8VAC
28VAC
24VAC
GND
+30VDC
3
4
1
X1dp
6
7
5
2
Output 2
Output 1
24VAC
X21:C32
X21:B32
X21:C31
+30VDC
X21:A32
GND
Input 2
Input 1
2
5
7
6
1
4
3
X21:C1
24VAC
X21:A2
Output 2
Output 1
X21:C1
+30VDC
X21:A1
GND
Input 1
Input 2
X20dp
+30VDC
GND
24VAC
00323584-xx
Conversion board, comp. table
2
5
7
6
1
4
3
X21:A31
X21:B31
24VAC
Output 2
Output 1
X21:C30
+30VDC
X21:B30
GND
Input 1
Input 2
X2dp
3
4
1
6
7
5
2
X21:C19
X21:B20
24VAC
X21:C20
Output 2
Output 1
+30VDC
X21:A20
GND
Input 1
Input 2
X10dp
2
5
7
6
1
4
3
X21:A3
X21:B3
X21:B2
24VAC
Output 1
Output 2
Input 2
GND
X21:C2
+30VDC
Input 1
X19dp
Status Modified Date Name Stand.
Check.
Date
Author
Orig./Repl.f/Replaced by
Mat. no.:
CAD file:
1.
2.
1.
02.11.02
30.05.05
02.11.02 Hi
Hi
Hi 30.05.2005
Hi
BT01-010201LD3
SCOM 2
n.u.
n.u.
n.u.
n.u.
n.u.
n.u.
n.u.
n.u.
n.u.
1
2
wh
to X36b:PE
2
11
2
3
4
PE
2
1
2
1
gnye
component table
00301239-xx
X8do
5
4
3
2
1
8
6
7
wh
br
V1
Key
Component table, mobile
00344982-xx
Placement System
S-27 HM
Doc. status
Product status
Function status
SIEMENS
L&A EA
00375221-xx
See page 4-15
See page 5-10
See page 3-6
See page 5-7 See page 5-9
See page 3-17
See page 3-19

2 - 35
BT01-010101LD3 Component table, mobile, lefthand side
+5VDC
+24VAC
+30VDC
GND
1
3
2
X1do
5
4
X23dp
2
5
3
4
1
X22dp
A17/A18/B17/B18/C17/C18
C32
A15/A16/B14/B15/C14/C15
A19/B18/B19/C18
A1
X2do
X21dp
28VAC
8VAC
8VAC
0V
28VAC
1
2
3
4
5
00301069-xx
(Cable)
8VAC
28VAC
0V
8VAC
28VAC
24VAC
GND
+30VDC
3
4
1
X1dp
6
7
5
2
3c
7b
6b
5b
4b
Y5
GE
GND (30V)
Y7
Y6
brrd&whbk
brbl&whrd
whbl
pkbr
2c
1a
7c
6c
5c
4c
EMERGENCY-STOP loop
bn
bl
Terminal panel,
5
6
X211
bn
bl
(Cable)
00322069-xx
1a
2a
Terminal panel,
N
L2
X206
(Cable)
00322067-xx
PE
gnye
00300379-xx
(Cable)
Control board, component table
X4do
3
4
6
X9do
3
1
2
4
5
5
4
X7do
2
3
1
(Cable)
00328753-xx
bn
X37a
3a
2a
X37a
Interface for comp.-handling
GND (5V)
Control unit
00326142-xx
assembly
Communications
4a
bn
00321428-xx
(Cable)
gn
wh
5
3
2
X5sd
wh
gn
bn
V-24
TxD
RxD
GND
(lefthand side)
00322063-xx
lefthand side
2a
3aRxD
gn
4aTxD
ye
gr&pk
rd&bk
bl
5a
7a
6a
+5VDC
+30VDC
GND (5V)
rdbl
grpk
vi
3b
2b
1b
C
B
A
whgr
whpk
yebr
whye
brgn
whgn
1c
BT02.DWG
Stromlaufplan/Circuit diagram
SMD Placement System SIPLACE S-27 HM
1
1
Component table, mobile,
6
8
7
9
13
14
F1
00323583-xx
GND (5V)
RxD
TxD
bn
ye
gn
pkbr
brrd&whbk
brbl&whrd
whpk
whbl
rdbl
grpk
vi
whgr
rd&bk
gr&pk
whye
yebr
whgn
brgn
bl
GND (5V)
GND (30V)
C
B
A
GE
Y5
Y7
Y6
+30VDC
+5VDC
bl
gnye
bn
5
11
4
3
2
1
10
9
7
8
6
28V/3A
8V/2A
0V
8V/2A
28V/3A 1
4
2
3
5
PE
230V
230V
115V
+5%
0V
-5%
gnye
1,5mm²
1,5mm²
gnye
F1 = 3.15 AT at 230VAC
F1 = 6.3 AT at 115VAC
to
table crosshead
X19dp
Sheet
Sh.
Status Modified Date Name Stand.
Check.
Date
Author
Orig./Repl.f/Replaced by
CAD file:
Mat. no.:
1.
2.
1.
02.11.02
30.05.05
02.11.02 Hi
Hi
Hi 30.05.2005
Hi
BT02-010201LD3
00364174-xx
SCOM 2
to tape cutter
n.u.
n.u.
n.u.
n.u.
n.u.
n.u.
n.u.
n.u.
n.u.
n.u.
00353088-xx
I/O distributor
voltages
00356643-xx
1
2
wh
to X36a:PE
24
gnye
PE
12
3
X36a
1
24
bl
gnyegnye
PE
L2 bn
12
3
X36a
1
component table
00301239-xx
Transformer
X8do
V1
Key
wh
br
5
7
8
6
2
4
3
1
S-27 HM
Placement System
Component table, mobile
00344982-xx
Doc. status
Product status
Function status
SIEMENS
L&A EA
00375221-xx
Output 2
Output 1
24VAC
X21:C32
X21:B32
X21:C31
+30VDC
X21:A32
GND
Input 2
Input 1
2
5
7
6
1
4
3
X21:C1
24VAC
X21:A2
Output 2
Output 1
X21:C1
+30VDC
X21:A1
GND
Input 1
Input 2
X20dp
+30VDC
GND
24VAC
00323584-xx
Conversion board, comp. table
2
5
7
6
1
4
3
X21:A31
X21:B31
24VAC
Output 2
Output 1
X21:C30
+30VDC
X21:B30
GND
Input 1
Input 2
X2dp
3
4
1
6
7
5
2
X21:C19
X21:B20
24VAC
X21:C20
Output 2
Output 1
+30VDC
X21:A20
GND
Input 1
Input 2
X10dp
2
5
7
6
1
4
3
X21:A3
X21:B3
X21:B2
24VAC
Output 1
Output 2
Input 2
GND
X21:C2
+30VDC
Input 1
See page 4-15
See page 5-10
See page 3-6
See page 5-7 See page 5-9
See page 3-17
See page 3-19

2 - 36
GS01-010201LD3 Tape cutter, pneumatically operated, righthand side
00356643-xx
voltages
Terminal panel
1
2
3
3
4
5
GND
+30VDC switched
(righthand side)
6a
5a
1c
7a
7b
1b
2b
3b
6b
bl
gr&pk
whgr
rd&bk
yebr
vi
grpk
rdbl
whye
+30VDC
+5VDC
GND (5V)
GND (30V)
Right comp. table
00344982-xx
Control board
00323583-xx
component table
+30VDC
+5VDC
GND (30V)
X7do
14
13
2
1
9
3
GND (5V)
GE
A
4
5
8
B
C
Y7
00322064-xx
X4do
3
6
4
bn
gn
ye
2a
3a
4a
(Cable)
00322072-xx
Control board, tape cutter
X3dq
00329699-xx
1
GND
X5dq
5
2
rd
bk
00332901-xx
(Cable)
X1
1
2
Left valve
LOGIC
piston retracted
Sensor switch
00332900-xx
00332900-xx
Sensor switch
piston extended
+5VDC
3
2
bn
bk
X7dq
+5VDC
3
bn
X8dq
2
bk
2
3
bn
gn
ye
Left cylinder
Signal
Signal
Right cylinder
piston extended
piston retracted
Sensor switch
00332899-xx
00332899-xx
Sensor switch
00332901-xx
(Cable)
2
1
SIEMENS
L&A EA
00375221-xx
GND (5V)
RxD
TxD
(Cable)
00328753-xx
righthand side
Sheet
Sh.
Status DateModified Name Stand. Orig./Repl.f/Replaced by
Check.
Date
Author
Mat. no.:
CAD file:
1.
2.
1.
02.11.02
30.05.05
02.11.02 Hi
Hi
Hi 30.05.2005
Hi
GS01-010201LD3
wh
to X36b:PE
00364174-xx
SCOM 2
~
1
Key
6
4
3
Key
4
4
6
5
5
6
GND
GND
1
1
bl
bl
1
Key
Key
3
4
6
~
(Cable)
00332900-xx
00332900-xx
(Cable)
~
~
1
bn
00332899-xx
(Cable)
bl
bn
00332899-xx
(Cable)
bl
Signal
Signal
1
GND
6
5
4
GND
6
5
4
Tape cutter, righthand side
00357163-xx
Doc. status
Product status
Function status
Right valve
X1
3
bk
2
X10dq
3
bk
X9dq
2
GND
5
2
rd
bk
X6dq
+5VDC
+5VDC
gy
4
pk
5
wh
10
bl
6
7a
7b
1b
2b
3b
6b
X37b
5a
3a
2a
X37b
Interface for comp.-handling
+5VDC
Y7
B
C
A
GE
GND (5V)
Control unit
00326142-xx
assembly
Communications
4a
bn
00321429-xx
(Cable)
gn
wh
5
3
2
X3sd
wh
gn
bn
V-24
TxD
RxD
GND
bn
gn
wh
gn
bn
wh
X207 X1dq
(Cable)
00313400-xx
GS01.DWG
Stromlaufplan/Circuit diagram
SMD Placement System SIPLACE S-27 HM
1
1
Tape cutter, pneumatically operated,
See page 4-15
See page 5-10
See page 5-12
See page 5-7
See page 3-17
See page 3-19