10 Machine Modules 10.2 Under Screen Cleaner Technical Training E by DEK 12/2017 99 10.2.3 Analysis Common error list Fig.8: Diagnose Blue Cleaner Error Description Possible Cause Action Cleaner unit not correctly “pick…

10 Machine Modules
10.2 Under Screen Cleaner
98 Technical Training E by DEK 12/2017
10.2.1.2 Overview Interchangeable Under Screen Cleaner Electrical System
Electrical Overview
10.2.2 Parts exchange / Settings / Calibration
Parts exchange Tools / Setting Calibration
Solvent Load Cell - Solvent full / empty calibration
Solvent Level Amp - Solvent full / empty calibration
Detail instruction in technical reference manual.

10 Machine Modules
10.2 Under Screen Cleaner
Technical Training E by DEK 12/2017 99
10.2.3 Analysis Common error list
Fig.8: Diagnose Blue Cleaner
Error Description Possible Cause Action
Cleaner unit not correctly
“picked Up”
●
Mechanical problem
●
Electrical or control problem
●
Calibration required
●
Check Reference point
Camera
●
Check Home Magnets
●
Check Parallelism
Cleaner / Camera axes
Home Position not found Play or difficulty with the Stencil
loading
●
Check home sensor
●
Check home magnet
●
Check Parallelism
Poor Cleaning results
●
Too much liquid
●
Too little cleaning liquid
●
Non consistent cleaning ( left
side cleaner that right)
●
Check that the required
amount of cleaning liquid is
used in the cleaning cycle
(settings, pump, air in
system)
●
Check Parallelism
●
Check distance to Stencil
●
Check paper quality
10.2.4 Maintenance
Maintenance tasks (Details instruction in reference manual).
Maintenance content Interval Requirement
Check cleaning functionality (all parts) monthly
Filter (225093) yearly

10 Machine Modules
Room for Your Sketches and Notes
100 Technical Training E by DEK 12/2017
Room for Your Sketches and Notes