Operation • Administrato r Functions 3—42 PS288 Owner’s Manual Figur e 3-58—V ib1 location 2b) Adjust the location of the probe tip so that it is centered on the device in the staging area of the left-most tube of V ibra…

Operation • Administrator Functions
PS288 Owner’s Manual 3—41
5e) In the Dimensions Reject Tray field, enter a value for Columns (X) and
Rows (Y) for the reject box/bin. These values set the number of reject
devices sent to the reject box/bin before the Reject is Full message is
displayed. In the example shown in Figure 3-57, the Reject is Full
message is displayed after 12 (6 x 2 = 12) devices are placed in the
reject tray.
Figure 3-57— Setting number of devices sent to reject tray
5f) Click the diagonal arrow. The PNP head moves to the lower right cor-
ner of the reject tray.
5g) Adjust the location of the probe tip so that it is centered at the lower
right corner of the reject tray. Use the up/down arrows for Y-axis
adjustments and the left/right arrows for X-axis adjustments.
5h) Click Save.
5i) When prompted, click Ye s to overwrite values.
Teach Tube Locations
1. Prepare the system—
1a) From the AH500 Setup window, select the Options tab.
1b) For main Input and Output media, select Tubes.
1c) For Reject 1, select Vibrator 2.
1d) In the Count of Fail Tubes field, enter the number of tubes in Vibrator
2 (output feeder) that will receive failed (reject) devices.
1e) Insert tubes in Vibrator 1 (input feeder) and Vibrator 2 (output feeder).
2. Teach Vibrator 1 locations—
2a) On the Gantry window, click Vib1.

Operation • Administrator Functions
3—42 PS288 Owner’s Manual
Figure 3-58—Vib1 location
2b) Adjust the location of the probe tip so that it is centered on the device
in the staging area of the left-most tube of Vibrator 1. Use the up/down
arrows for Y-axis adjustments and the left/right arrows for X-axis
adjustments.
2c) Click Save.
2d) Click the Tubes tab.
2e) In the Columns (X) field, enter the number of tubes in Vibrator 1.
2f) In the Chips/Tube field, enter the number of devices per tube.
2g) Click the diagonal arrow. The PNP head moves to the right-most tube
in Vibrator 1.
2h) Adjust the location of the probe tip so that it is centered on the device
in the staging area of the right-most tube. Use the up/down arrows for
Y-axis adjustments and the left/right arrows for X-axis adjustments.
2i) Click X,Y AutoFind.
2j) If the new values for X and Y are >±5, press Yes and repeat Step 2h to
Step 2i.
If the new values for X and Y are <±5, press No.
3. Teach Vibrator 2 locations—
3a) On the Gantry window, click Vib2.
3b) Adjust the location of the probe tip so that it is centered on the device
in the staging area of the left-most tube of Vibrator 2. Use the up/down
arrows for Y-axis adjustments and the left/right arrows for X-axis
adjustments.
3c) Click Save.
3d) Click the Tubes tab.
3e) In the Columns (X) field, enter the number of tubes in Vibrator 2.
3f) In the Chips/Tube field, enter the number of devices per tube.
3g) Click the diagonal arrow. The PNP head moves to the right-most tube
in Vibrator 2.
3h) Adjust the location of the probe tip so that it is centered on the device
in the staging area of the right-most tube of Vibrator 2. Use the

Operation • Administrator Functions
PS288 Owner’s Manual 3—43
up/down arrows for Y-axis adjustments and the left/right arrows for
X-axis adjustments.
3i) Click X,Y AutoFind.
3j) If the new values for X and Y are >±5, press Yes and repeat Step 3h to
Step 3i.
If the new values for X and Y are <±5, press No.
Teach Shuttle Transfer Locations
1. Teach locations—
1a) On the Gantry window, click Shu. The PNP head moves to the marking
shuttle.
1b) Adjust the location so the probe tip is centered on Shuttle Ped 2 in the
marking pedestal. Use the up/down arrows for Y-axis adjustments and
the left/right arrows for X-axis adjustments.
1c) Click Save.
1d) Click Park. The PNP head moves to the Park location.
1e) Select the Label or Laser tab (depending on which type of marking
system is installed). Click the Vacuum switch to ON. See Figure 3-59.
Figure 3-59— Vacuum switch ON
1f) Insert a device in Programmer 1.
1g) Click P1. The PNP head moves to Programmer 1.
1h) Right-click the touchpad to pick up the device.
1i) Click Shu. The PNP head moves to the marking shuttle.
1j) Right click to place the device on Shuttle Ped 2.
1k) On the Actuator tab, click Z AutoFind. The PNP head lowers and the
probe tip touches the device.
1l) Click Yes to save the new values. The Z-axis reference position is now
set.
1m) Click X,Y AutoFind. The PNP head picks the device, takes it to Vision
system and compares the orientation of the device to the orientation in
the reference vision file.
1n) If the new values for X and Y are >±5, press Ye s and repeat Step 1m.
If the new values for X and Y are <±5, press No.