PS288_OwnersMnl_PriorTo2009 - 第44页
Set Up • (Optional) Setting Up the Tape Input Feeder 2—10 PS288 Owner’s Manual Before running a job for the first time, it is necessary to: • T each locations to the PNP head. For information, see “T each the Pack- age F…

Set Up • (Optional) Setting Up the Tube Input and Tube Output Modules
PS288 Owner’s Manual 2—9
5b) Adjust the output tube unloader platform front and rear tube guides as
described in Step 4 above.
6. Insert tubes—
6a) Insert full tubes into the input tube loader platform.
6b) Insert empty tubes into the output tube unloader platform.
6c) Close the safety shield.
NOTE: The pin 1 orientation for devices is set in the package file.
Devices should be loaded in tubes as defined in the package file.
NOTE: If this is the first time you are installing tube feeders on
your PS288, you may need to edit the WinAH400.ini file to reflect
this additional option. Proceed with Step 7.
If you have previously installed tube feeders on your PS288, skip to
Step 8.
7. Configuring AH500 after first tube feeder installation—
7a) Make a backup copy of WinAH400.ini: e.g., WinAH400backup.ini.
7b) Using Windows Explorer, open C:\AH400_32\WinAH400.ini.with
NOTEPAD editor.
7c) Locate the section
;------- tube media settings -----
7d) Ensure that the value for Tube Feeder 1 (input tube feeder) is
STDIN. Change if it is not.
7e) Ensure that the value for Tube Feeder 2 (output tube feeder) is
STDOUT. Change if it is not.
7f) Save the WinAH400.ini file and exit Windows Explorer.
8. Configuring AH500 after repeat tube feeder installation—
8a) On the Options window, select "Tubes" for the input and output media.
8b) If the vision system will be used to check every device, set Vision Sys-
tem to ON.
8c) If the vision system will be used to check only the first and last devices
in a tube, set Vision System to OFF and check “1st +last 2 /tube.”
9. Adjust vibration controls—
If devices do not travel freely in the input tubes or the output tubes,
increase the vibration by turning the vibration controls clockwise. The
magnitude of vibration is set by adjusting V1 for the input tubes and
V2 for the output tubes.
NOTE: Within AH500’s Gantry window, Vibrator 1 is represented
by the yellow position label Vib1. Vibrator 2 is represented by the
yellow position label Vib2.
This completes the procedure for setting up a tube input and tube output
modules.

Set Up • (Optional) Setting Up the Tape Input Feeder
2—10 PS288 Owner’s Manual
Before running a job for the first time, it is necessary to:
• Teach locations to the PNP head. For information, see “Teach the Pack-
age File” on page 3-33.
(Optional)
Setting Up the
Tape Input
Feeder
The PS288 can be configured with an optional tape input feeder. The tape
input feeder is installed on the front of the PS288.
Tape input feeders are available in 8, 12, 16, 24, 32, 44, and 56 mm sizes to
match device tape of those widths. The last two digits of the tape input
feeder part number indicate the tape width. For example, a 32 mm tape input
feeder has a part number ending in 32. See Figure 2-11.
Figure 2-11—Part number for 32 mm feeder
To install the tape input feeder:
1. For first-time installation—
If the tape input feeder is being installed for the first time on your
PS288, the WinAH400.ini file may need to be edited to reflect this
additional option.
1a) Using Windows Explorer, open C:\AH400_32\WinAH400.ini with
NOTEPAD editor.
1b) Locate the section
;------- tape input/output -----
1c) Ensure value for Tape Advance Installed is TRUE, as shown.
TapeAdvanceInstalled=TRUE
1d) Save the WinAH400.ini file and exit Windows Explorer.
2. Prepare the system—
2a) From the Handler Computer interface, stop any Job that is running and
exit to the main window as shown in Figure 2-12.
Part number

Set Up • (Optional) Setting Up the Tape Input Feeder
PS288 Owner’s Manual 2—11
Figure 2-12—Main window
2b) Remove the two screws holding the small safety shield that covers the
tape input feeder slot.
Figure 2-13—Remove two screws holding small safety shield
2c) Remove the small safety shield and set it aside. It is not used when the
tape input feeder unit is installed.
3. Mount the feeder unit—
3a) Align the rail on the bottom of the feeder unit with the channel in the
base plate.
3b) Slide the feeder unit down the channel until the feeder unit reaches the
front wedge. See Figure 2-14.