The printer must be powered OFF before mounting the rewinder.
During operation, the rotating axle is openly accessible !
Therefore, keep long hair, loose clothes, and jewelry away from the moving parts !
Before connecting the rewinder to the power supply, make sure the voltage
selected on the power module corresponds with the supply voltage !
F
Mounting the Printer Adapter
In order to operate the external rewinder, an adapter unit has to be mounted on to
the Apollo.
Fig. 13 b Mounting the printer adapter
1. Attach upper adapter plate (2) to the lower adapter plate (3) using the
knurled screws (1). Put the screws through the circular holes in the upper
adapter plate.
2. Rotate the accessory lock/release lever (7) counter-clockwise until it stops.
3. Remove the tear-off plate (4) from its mountings (6).
4. Insert the printer adapter plate (5) into the mountings (6).
5. Turn the lock/release lever (7) clockwise until it stops.
6. Adjust the lower adapter plate (3) vertically until only a space of about .08
in or 2 mm is left between the adapter plate and the standing area.
7. Tighten the screws (1).
4
5
6 7
1 32
81
cab - Produkttechnik GmbH / Tharo Systems, Inc.
Set the switch (5) to the required method of rewinding :
- Rewind with labels on the outer side of the silicon liner
- Rewind with labels on the inner side of the silicon liner
Mounting the Guide Bar
1 2 3 4
1 - Rewinder
2 - Upper threaded hole
3 - Guide bar
4 - Screw (incl. washer)
Fig. 13 c Mounting the guide bar
Using the hex screw (4) and washer provided, secure the guide bar (3) into the
upper one of the two threaded holes (2) located on the inside of the rewinder's side
cover. A hexagonal wrench is provided.
Selecting the Method of Rewinding
The external rewinder allows rewinding of labels in both ways, inside and
outside winding.
5
Fig. 13 d Selecting the method of rewinding
82 cab - Produkttechnik GmbH / Tharo Systems, Inc.
If you have switched the operating voltage of your rewinder you need to
replace the fuses. For the standard setting of 230V, two fuses rated at
500mAT must be used. For operation at 115V, two fuses rated at 1AT must
be used. (Both types of fuses are shipped with the rewinder, one of
which is installed depending on the voltage setting.)
To alter the voltage, open the cover (3) and remove the voltage selector.
Replace the fuses as explained above. Slide the voltage selector back into the
power supply module so that the correct voltage is visible in the lid window.
Connect the rewinder to a grounded outlet using the power cable supplied in the
accessories package.
Connecting the Rewinder to the Power Supply
The rewinder operates with a supply voltage of 230V/ 50Hz or 115V/ 60Hz.
Before connecting the rewinder to the power supply, make sure that the
voltage selected on the power supply module is the same as your main
power supply !
Fig. 13 e Power supply module of the external rewinder
1 - Power supply
connector
2 - Power switch
3 - Voltage selector cover
The current voltage setting of the power module is visible in the lid window (3).
F
1 2 3
F