8-19 Feeder Setup Used for moving the selected object to the assigned position of coordinates by rotating XY axis driving motor , or for obtaining th e present coordinates of the selected object. <Light> comb o b…

8-18
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
1. <Feeder Base>
Displays the feeder base where the corresponding stick unit is installed currently.
The numbers displayed are as follows.
0: Not installed on any feeder base.
1: Installed on Feeder Base (Front Feeder Base) 1.
2: Installed on Feeder Base (Rear Feeder Base) 2.
2. <Slot No.>
Displays the slot number of the feeder base where the corresponding stick unit is
installed currently. The numbers displayed are as follows.
0: Not installed in any slot.
1 - 52: Installed in the corresponding number slot.
3. <Change…> button
In the case of installing stick unit to the feeder base, change the feeder base unit
and slot number to install. When this button is clicked on, the following dialog
box is displayed.
<Install Feeder Base> group
Feeder Base
Displays the feeder base where the corresponding stick unit is installed
currently. The numbers displayed are as follows
0: Not installed on any feeder base.
1: Installed on Feeder Base (Front Feeder Base)1.
2: Installed on Feeder Base (Rear Feeder Base)2.
Slot No.
Designates the order in which the stick feeder is installed.
<Update> button
Saves the set contents and closes the dialog box.
<Cancel> button
Closes the dialog box without saving the set contents.
<Teach> group

8-19
Feeder Setup
Used for moving the selected object to the assigned position of coordinates by rotating
XY axis driving motor, or for obtaining the present coordinates of the selected object.
<Light> combo box
Setup illumination of fiducial camera to be used for teaching. Please refer to
“7.1.1 Common Align Data” for more information.
combo box
Used for selecting the object to move to the designated coordinates by rotating the
XY axis driving motor or to select the object for which the present coordinates is
searching. Selectable objects are as follows:
Fid Cam1/2: Select the fiducial camera.
Head 1 ~ Head 10: Select #1 ~ #10 heads.
<Move> button
Move the object selected in the combo box to the position of the assigned
coordinates. Before executing <Move> button, the cell in the grid (Coordinates for
pickup point of stick feeder) corresponding to the desired position must be clicked
on.
<Get> button
Obtain coordinates for XY axis with reference to the object selected in the combo
box. At this time, Before executing <Get> button, the cell in the grid (Coordinates
for pickup point of stick feeder) corresponding to the desired position must be
clicked on.
<Pick> button
Picks up parts from the presently selected stick feeder. At this time, the head (Device)
to pickup the part must be selected first. When the pick-up is successful, the following
dialog box is displayed.
Please refer to“8.1.1 Feeder Base” of <Pick> button for more information.
<2Pt. Teach…> button
When teaching the pick-up position of the stick feeder, the center point is calculated
by teaching two corner points at opposite angles of the pocket with the component.
Please refer to “8.1.1 Feeder Base” of <2Pt. Teach…> button for more information.
<Offset> button
Applies the offset collective to the Z axis coordinate of the pickup point of the feeder
selected from the <Grid> group.

8-20
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
<Z> edit box
Enters the offset value.
<OK> button
Saves the edited contents and closes the dialog box.
<Cancel> button
Closes the dialog box without saving the edited contents.
<Z Teach> button
Measures the Z axis height for the pickup point of feeder automatically using
pneumatic pressure. Insert the CN040 nozzle into the nozzle holder of the head and
select the tape feeder for which Z axis height is to be measured from the <Grid> group
and then click the <Move> button.
<Panorama View> button
In the case of a large part for which pocket teaching is impossible, its entire shape is
not displayed in the vision window. In this case, it is possible to display the part shape
in on one vision window by performing split recognition of the part shape and
composing the split images into one using this function.
<Part Outline> check box
If this check box is selected, when the fiducial camera is moved to the position of the
corresponding feeder to check the pickup position, the outline image that considers the
angle at which the corresponding part is picked up is displayed on the SMVision
window.
Panorama General