DECAN_S1_Administrator′s_Guide(Eng_Ver1.5)_Print.pdf - 第358页

13-6 Next Generation, Multi-Functional Plac er DECAN S1 Administrator’s Guide  'Part Info.' Group Double-click the part to modify the data.  <PCB D/L> button Starts production afte r downloading the PCB…

100%1 / 632
13-5
Production Setup
equipment.
If the equipment is paused by clicking the <PCB Stop> button, when starting the
work, click the <PCB Restart> button first and then press the 'START' button.
<Inhibit Board Entry> check box
Check this box to stop PCBs from entering the transport rail automatically from an
upstream transport rail or board station. If the equipment is temporarily stopped by
this function, the equipment state is changed into “RUN_RDY” state.
The shutdown of the equipment in “RUN_RDY” state is not included in the
shutdown count of the equipment.
<Sample Production> check box
If you select this option and proceed to production, the machine will stop at each
cycle in the event of a part recognition error or a pick-up error.
In the 'Sample Production Mode Align Error List' dialog box that appears this
time, the data or step of the part can be changed to re-install the part without
discarding it.
The items that can be corrected in the 'Sample Production Mode Align Error List'
dialog box are as follows:
Edit part data
Dump part during pickup
Edit individual or array step coordinates
Download edited step and part data
13-6
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
'Part Info.' Group
Double-click the part to modify the data.
<PCB D/L> button
Starts production after downloading the PCB.
<Teach> group
Selects a device and teaches the mounting point.
<Dump> button
Dumps a part during pickup.
<Apply Offset To All Array Steps> button
Apply the edited steps to all arrays.
<Sample Production(Next)> check box
Stops using the function from the next cycle.
<One Time Calibration> check box
Tick this check box to perform “Runtime Calibration” at the start of production.
The “Runtime Calibration” function is performed only once. To perform “Runtime
Calibration” again, press the “STOP” button, tick this check box and press the
“START” button again.
<LCR Check Reset> button
Selecting this button deletes the LCR Check data, which is mainly used to initialize
production data.
If LCR Check data is deleted, LCR Check is performed upon starting the next
production.
<One Time Skip> button
Skip only the new PCBs fed to the equipment temporarily without placing them. Since
separate setup is needed to enable this function, our C/S department must first be
contacted.
When using this function, the following pre-requisitions shall be satisfied:
13-7
Production Setup
Small PCB (substrate) that is set to ‘Work’ among array PCBs that use no bad mark
Small PCB (substrate) to which ‘One-Time-Skip’ function is applied in the ‘PCB
Array’ dialog box is already set up
PCB download completed.
When these pre-requisitions are met, the ‘One-Time-Skip’ function is applied after
auxiliary menu of ‘Start’ or ‘Cont.’ is selected, and the placement is performed.
Clicking the button will display the following dialog box.
<1. Array> group
Sets whether to perform placement on small PCBs in the array PCB.
<No> column
Refers to each small PCB in the array PCB. It is created as many as the
number of small PCBs.
<Skip> column
Allows the small PCB selected in this column to be skipped without being
placed during placement and sets the small PCB indicated in the <2.Array
Layout> group to ‘Skip’.
<One Time Skip> column
Of the small PCBs set to ‘Work’ in the array PCB, it allows only the new PCB
fed to the equipment to be skipped temporarily without being placed.
In order to use the ‘One-Time-Skip’ function, select the corresponding small
PCB and click the <One Time Skip> button in the ‘Product Monitor’ tab
dialog box.
<2. Array Layout> group
Selects the small PCBs in the array PCB using the mouse. It indicates whether
currently set placement work has been performed or not on the small PCBs.