13-12 Next Generation, Multi-Functional Plac er DECAN S1 Administrator’s Guide  <SET> button Scenarios fo r using this feature are as follows: 1)Prepare 2 PCB files that meet the above conditions. 2)Select the &lt…

100%1 / 632
13-11
Production Setup
Caution This function allows the placement to be simply performed
continuously. If interference is expected in the future
between the skipped part and the nearby placed parts while
performing placement, release this function.
<Bad Mark Transferring> check box
This function is used when a scanner made by D-TEK is used. For more details
regarding this, contact us.
<Self Board Fiducials> check box
When the machine operation mode is 'Join', select this check box in order to
increase the part placement accuracy by having the front and rear gantries
recognize the fiducial marks on the PCB respectively.
<Soft Ground> check box
When the machine is installed at a location of soft ground, selecting this check box
will reduce the vibration and noise that occurs due to instantaneous acceleration of
the XY axes.
<PCB Transfer Speed> combo box
Used to adjust the PCB feeding speed. When the PCB is heavy, if it is selected at too
high speed, the conveyor belt may not feed the PCB sufficiently with the belt rotating
while slipping. The default selection is Middle. Adjust the speed appropriately, if
necessary.
Fastest: very high speed
Fast: high speed
Middle: medium
Slow: low speed
<Speed> slide bar
Select the driving speed of the XY axis driving motor.
<Z Axis Mount Delay> slide bar
Works after adding the defined value in the slider bar to the placement delay value
setup in the common data at the time of part registration. This value is applied only to
Z-axis.
<Progressive Product> check box
This function can only be used when the conveyor type is Sigle Lane and a docking
cart is used.
This function is used to proceed with production with one equipment unit
using two PCB files with different steps and feeder arrangements on one PCB.
13-12
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
<SET> button
Scenarios for using this feature are as follows:
1)Prepare 2 PCB files that meet the above conditions.
2)Select the <Product>-<Option Setting>-<Progressive Product> check box and select
the <SET> button.
3)Load the PCB files you want to produce in JOB A and JOB B.
4)Open the PCB file to be produced first and start production.
At this time, check if it is displayed as JOB_A: the name of the PCB to be
produced first in the PCB information on top of MMI after downloading RT.
5)When PCB production is completed, use the Docking Change Dialog to connect the
docking cart to be used on the second PCB and select Continue.
At this time, check if it is displayed as JOB_B: the name of the PCB to be
produced second in the PCB information on top of MMI after downloading RT.
<Detail> button
This button is used to select the image viewed in the SMVision window during PCB
production.
<Mode> combo box
Camera
Selected when looking at the image of a specific camera. Select the
13-13
Production Setup
corresponding camera from the <Device> combo box.
Head
Selected when looking at the image in which the part picked up by a specific
head is recognized. Select the corresponding head from the <Device> combo
box.
Camera Error
Selected when looking at the image of part recognition error from a specific
camera.
It shows the recognized part image according to the placement order during
placement. However, if the placement is completed, the camera selected in the
following <Device> combo box shows the part image error that occurred last.
Head Error
Selected when looking at the recognition error image of part picked up by a
specific head.
It shows the recognized part image according to the placement order during
placement. However, if the placement is completed, it shows the image of part
recognition error that occurred last among the parts placed by the head
selected in the following <Device> combo box.
Last Error
It shows the recognized part image according to the placement order during
placement. However, if the placement is completed, it shows the image of part
recognition error that occurred last during placement.
System
Shows the part recognition image according to the placement order.