DECAN_S1_Administrator′s_Guide(Eng_Ver1.5)_Print.pdf - 第374页

13-22 Next Generation, Multi-Functional Plac er DECAN S1 Administrator’s Guide 13.5. Finish [F5] This submenu transmits to the equipment the command to completely stop the placement related to the downloaded PCB data.

100%1 / 632
13-21
Production Setup
13.4. Cont. [F4]
When the “PCB Download” operation has been completed, this button is activated while
the placement is not in progress, and it is inactivated while the placement is in progress.
This command transmits the command to continue the placement related to the
downloaded PCB data at the position where the operation was stopped previously to the
equipment.
The cases that “Cont.” command is not available are as follows:
When a new PCB file is downloaded
When the number of Cycle is changed
When the number of Cycle is changed
“Cont.” command is available is for the following case
When the step data related to head or feeder or nozzle or skip is changed
13-22
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
13.5. Finish [F5]
This submenu transmits to the equipment the command to completely stop the placement
related to the downloaded PCB data.
13-23
Production Setup
13.6. T/F Cnt [F6]
Set the start position of the pocket on the tray feeder to pick up the component. When this
button is clicked on, the following dialog box is displayed.
Figure13.7 “Tray Count Information” dialog box
1: Grid group
<Select> option button
Select the tray feeder unit to set. The tray feeder unit follows the setup of the tray
feeder registered in the Tray dialog box of the System Setup menu.
<Grid> group
Set the position of the pocket to start.
<Step> column