14-5 Machine Calibration Sets the Y offset value. Set the Y positio n of the head1 to 0 when the XY axes reach and set this value as a reference.  <Z> column Sets the Z offset value. Set the PCB top su rface as th…

100%1 / 632
14-4
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
14.1.2. <Head Offset> Tap dialog box
Setup the offset for the mechanical characteristics of each head. The head offset
information displayed here, with the exception of that for the Z and R axes is updated
automatically if the head offset calibration is executed during camera calibration and the
result value is reflected.
Caution Do not modify data in the actual placement of each head at
user’s discretion, as damage to head or defective work may
occur if the setup value has changed by the user when
placement is being performed based on the offset value.
Figure14.2 “Head Offset” tab dialog
1: Grid group
<Gantry> combo box
Selects the gantry for which setup will be performed.
<Grid> group
Sets the offset between heads.
<Head> column
Displays the head number.
<X> column
Sets the X offset value. Set the X position of the head1 to 0 when the XY axes
reach home and set this value as a reference.
<Y> column
14-5
Machine Calibration
Sets the Y offset value. Set the Y position of the head1 to 0 when the XY axes
reach and set this value as a reference.
<Z> column
Sets the Z offset value. Set the PCB top surface as the reference of the offset value
when the PCB is loaded.
<R> column
Sets the R offset.
<Other Device> group
Sets the offset values of devices other than the head.
<Fiducial Cam> edit box
Sets the XY offset value of the Fiducial camera.
<From Ref. Camera> check box
Indicates the XY data in the ‘Grid’ group with the center of ‘Fiducial Camera 1’ as
a base.
<Teaching Beam> group
Sets the items related to the teaching beam (Height Sensor).
<X> edit box
Input the X coordinate of the teaching beam.
<Y> edit box
Input the Y coordinate of the teaching beam.
<Z> edit box
Input the Z coordinate of the teaching beam.
<Use> check box
Sets whether to use the teaching beam (Height Sensor). This function is enabled in
machines in which a height sensor is installed.
<Initialize Offset> button
This button is only displayed when you log in in “Service” mode. This is used to reset
the fiducial camera offset and head offset to their default values. When you click this
button, the following dialog box is displayed.
If you click the <Yes> button, the fiducial camera offset and head offset are set to their
14-6
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
default values.
Erased data cannot be restored. Fiducial Camera Offset Calibration and Head Offset
Calibration must be performed again to apply the fiducial camera offset and head
offset.