DECAN_S1_Administrator′s_Guide(Eng_Ver1.5)_Print.pdf - 第403页

14-21 Machine Calibration 8. Click the <Update> button.

100%1 / 632
14-20
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
5. After confirming that there is no object inside the machine or on the conveyor, click
the <OK> button.
6. Click the <Yes> button.
7. Limit value is measured for each axis. Click the <Yes> button.
14-21
Machine Calibration
8. Click the <Update> button.
14-22
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
14.3.2. Skew compensation
Skew means compensating the skew occurred horizontally in the X-axis frame against the
Y1-axis and Y2-axis after movement of equipment. This must be done upon initial
installation and after movement of the equipment to a new location. Method of skew
compensation for Y-axis is as follows;
Caution Skew means compensating the skew occurred horizontally
in the X-axis frame against the Y1-axis and Y2-axis after
movement of equipment. This must be done upon initial
installation and after movement of the equipment to a new
location. Method of skew compensation for Y-axis is as
follows;
14.3.2.1. Procedure
Skew Compensation method is as follows.
1. First, move the X frame manually to the center of equipment.
2. Click the <Skew Compensation> button.