14-44 Next Generation, Multi-Functional Plac er DECAN S1 Administrator’s Guide 14.3.8.1. Fix Camera Calibration (Scale & Rotation & Position) Calibrate the Scale (um/pixel), Rotation (deg ) and Position (mm) of t…

100%1 / 632
14-43
Machine Calibration
Figure14.12 “Head/ Camera/ Light Calibration” dialog box
1: Head/ Camera/ Light Calibration” dialog box
<Calibration Menu> group
Select an item to be calibrated. If you click the button of a specific item, the
description on the works to be performed are displayed in the message box in order.
Follow the instructions to complete the calibration.
<Gantry> combo box
Select the Gantry for performing Calibration
<Target Camera> combo box
Select the camera to set light value.
<Light…> button
Set the light value for the selected camera.
14-44
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
14.3.8.1. Fix Camera Calibration (Scale & Rotation & Position)
Calibrate the Scale (um/pixel), Rotation (deg) and Position (mm) of the Fix Camera. In
order to calibrate the Fix Camera, a dedicated fiducial mark jig must be used. (CNT20
Nozzle)
Perform calibration of the Fix Camera in the following manner:
1. Click the <Nozzle Prepare> button.
2. Click the <OK> button.
3. Click the <Next> button to move down the Z axis of the head in order to remove all
nozzles inserted in the nozzle-holder manually.
Then, after the head assembly moves to the designated position, move all Z-axes
down. At this time, remove all inserted nozzles manually
14-45
Machine Calibration
4. The message “Set Calibration Tool into hole 1 of ANC1” appears. After installing the
CNT20 nozzle in hole 1 of ANC1, click the <OK> button.
5. After selecting the <Automatic Next> check box, click the <5. Fix1 Cam.> button.
6. The calibration is performed automatically. If it is completed, the calibration result is
displayed as shown in the following figure. Click the <Update> button to apply the
new calibration value.