Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
14-57
Machine Calibration
5. The calibration is performed automatically. If it is completed, the calibration result
is displayed as shown in the following figure. Click the <Update> button to apply
the new calibration value.
6. If the calibration procedure is completed properly, the result as shown in the
following figure is displayed and then the message, “Fid-Cam Offset
Calibration(Using Hole) is Finished.”.
14-58
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
Memo The reference values for the calibration of the Camera Offset is as
follows.
Gantry 1
Offset X: -189.5 ~ -187.5 (mm)
Offset Y: -1.0 ~ 1.0 (mm)