14-69
Machine Calibration
4. If the calibration procedure is completed for all fly-cameras normally, the result is
displayed as shown in the following figure. Click the <Update> button.
14-70
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
The result value can be confirmed in the Camera dialog box in the System Setup
menu.
Memo The range of the reference values for the ‘fly-camera calibration’ is as
follows:.
Fly Camera FOV 20.3mm(MEGA) (μm/pixel)
Scale X: 19.22 ~ 20.18
Scale Y: 19.22 ~ 20.18
14-71
Machine Calibration
14.3.8.8. Fly Camera Offset Calibration
The following is the procedure to calibrate the offset of the fly Camera. To perform Fly
Camera Offset Calibration, first confirm that the CNT20 nozzle is installed in ANC Hole
No.1 before operation.
The following is the procedure to calibrate the ‘Fly-Camera to Offset.
1. If the CNT20 nozzle is not installed, click the <Nozzle Prepare> button to manually
insert the CNT20 nozzle into ANC Hole No.1.
2. If the <14. Fly Camera Offset > is clicked after selecting the <Automatic Next> check
box, calibration is performed for the selected gantry automatically.