16-6 Next Generation, Multi-Functional Plac er DECAN S1 Administrator’s Guide 16.3. Light [F4] Checks the lighting devices in stalled on the fiducial camera, fly camera, and fix camera. Figure16.6 “Camera Light Diagnosis…

16-5
Diagnosis
16.2. Conveyor [F3]
Checks the status of various devices in the conveyor group. When this submenu is selected
on, the following dialog box is displayed. Please refer to“4.5 Conveyor ” for more
information.

16-6
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
16.3. Light [F4]
Checks the lighting devices installed on the fiducial camera, fly camera, and fix camera.
Figure16.6 “Camera Light Diagnosis “dialog box
<Camera Select> combo box
Select the camera on which the lighting device to be checked is installed.
Fid Cam1/2: Select the fiducial camera.
Head 1 ~ Head : Select #1 ~ #10 heads.
Fix Cam1: Select the fix camera.
<Light Value> group
Set the light value.
When the fiducial camera is selected, the range of light level that can be set is as
follows.
<Outer>: The range of the Outer light level is 0~15.
<Inner>: The range of the Inner light level is 0~15.
When the fly camera is selected, the range of light level that can be set is as follows.
<Side>: The range of the side light level is 0~15.
<Outer>: The range of the Outer light level is 0~15.
<Coaxial>: The range of the Coaxial light level is 0~15.
When the fix camera is selected, the range of light level that can be set is as follows.

16-7
Diagnosis
<Side>: The range of the side light level is 0~15.
<Outer>: The range of the Outer light level is 0~15.
<Inner>: The range of the Inner light level is 0~15.
<Close> button
Closes the dialog box.