00197501-02_AI_WPC_Umbau_X-Series_S_DE_EN - 第74页

Review 3 Setting up and Commissioning 3.3 Fitting the CAN Switch 74 Assembly Instructions / Montageanleitung SIPLACE WPC an SIPLACE X-Serie S SIPLACE WPC on SIPLACE X Series S 03/2020 Fig.23: Power supply on the X121 ► …

100%1 / 94
Review
3 Setting up and Commissioning
3.3 Fitting the CAN Switch
Assembly Instructions / Montageanleitung SIPLACE WPC an SIPLACE X-Serie S SIPLACE WPC on SIPLACE X
Series S 03/2020
73
Fig.20: CAN bus on X1
Fix the CAN bus cable [03112552-xx]
(1)
for the CAN bus X1 on the CAN bus
terminator.
Fig.21: Connection for cable [03105018-xx]
Connect the cable [03105018-xx] from
X1 on the CAN switch to X3 (X1*6) on
the COT insert (2)
.
Connect the cable [03105018-xx] from
X1 on the CAN switch to X2 (X126) (1)
.
Fig.22: COT insert on X125
Connect the COT insert from X1*5 to
X125 (1)
.
Review
3 Setting up and Commissioning
3.3 Fitting the CAN Switch
74 Assembly Instructions / Montageanleitung SIPLACE WPC an SIPLACE X-Serie S SIPLACE WPC on SIPLACE X
Series S 03/2020
Fig.23: Power supply on the X121
Connect the power supply X1*1 to
X121 (1)
.
Fig.24: Signaling circuit X123 on X1*3
Connect the safety circuit and the sig-
naling circuit X123 to X1*3 [03112551-
xx] (1)
.
Fig.25: Intermediate connector on CAN switch
1. Power supply X1*1 on X121
2. X122 on X1*2
3. X3 to X1*6
4. X125 on X1*5
Connect the intermediate connector
X122 to the power supply on the CAN
switch with X1*2 on the COT insert (2)
.
Review
3 Setting up and Commissioning
3.3 Fitting the CAN Switch
Assembly Instructions / Montageanleitung SIPLACE WPC an SIPLACE X-Serie S SIPLACE WPC on SIPLACE X
Series S 03/2020
75
Fig.26: Pneumatic hoses on fixed table
To do this, pull the unused pneumatic
hoses out of the machine.
Remove the cover from the pneumatic
hoses.
Connect the pneumatic hoses (1) for
the fixed table.
The X10bn connection remains open.
Fix the cable into place with the cable ties so that nothing can be pinched or rubbed.