NPM-W 2 EJM7DE-MB-04M-00 4-1-1 -5 Adjusting the air pressure (press ure of cleaning blow , line camera air and vacuum break ) Tool used: Phillips sc rewdriver (No.2) , spanner (10 mm) Time requir ed: 5 minutes ● Adjust w…

100%1 / 572
NPM-W2 EJM7DE-MB-04M-00
4-1-1-4
Every
24
hours
PeriodicPeriodic
inspection
NPM-W2 EJM7DE-MB-04M-00
4-1-1-5
Adjusting the air pressure (pressure of cleaning blow , line camera air and vacuum break )
Tool used: Phillips screwdriver (No.2), spanner (10 mm) Time required: 5 minutes
Adjust when the cleaning blow pressure and line camera air pressure is out of required value range.
Before
opera-
tion
Maintenance
4-1-1
Inspecting the
pressure gauge 3
1
3
Front side
Attach the cover inside
of the cart
Image as seen from the
arrow direction
6
9
7
Remove the
feeder cart
(P.3-2)
Attach the feeder
cart (P.3-2)
Screw: Four locations
Tighten screws
Cover
OFF
SERVO
2
SERVO
ON
8
NPM-W2 EJM7DE-MB-04M-00
Front side
Remove the cover
inside of the cart
Image as seen from the
arrow direction
4
Adjust the pressure to be
within the range
5
Cleaning blow regulator
knob
How to use the regulator knob
1: Pull the knob up
2: Adjust it
3: Pull it down
(For cleaning blow pressure)
4-1-1-6
Screw: Four locations
Remove screws
Vacuum break
pressure regulator
knob
Lock nut
When the vacuum break regulator
is adjusted, loosen the lock nut.
After adjusted, tighten the nut.
Cleaning blow air
pressure
(0.13 ~ 0.14 MPa)
Cover
Every
24
hours
PeriodicPeriodic
inspection