N7201A617E00_0317 - 第136页
NPM-W 2 EJM7DE-MB-04M-00 4-1-1 -5 Adjusting the air pressure (press ure of cleaning blow , line camera air and vacuum break ) Tool used: Phillips sc rewdriver (No.2) , spanner (10 mm) Time requir ed: 5 minutes ● Adjust w…

NPM-W2 EJM7DE-MB-04M-00
4-1-1-4
Every
24
hours
PeriodicPeriodic
inspection

NPM-W2 EJM7DE-MB-04M-00
4-1-1-5
Adjusting the air pressure (pressure of cleaning blow , line camera air and vacuum break )
Tool used: Phillips screwdriver (No.2), spanner (10 mm) Time required: 5 minutes
●Adjust when the cleaning blow pressure and line camera air pressure is out of required value range.
Before
opera-
tion
Maintenance
4-1-1
Inspecting the
pressure gauge 3
1
3
Front side
Attach the cover inside
of the cart
■Image as seen from the
arrow direction
6
9
7
Remove the
feeder cart
(→P.3-2)
Attach the feeder
cart (→P.3-2)
●Screw: Four locations
●Tighten screws
Cover
OFF
SERVO
2
SERVO
ON
8

NPM-W2 EJM7DE-MB-04M-00
Front side
Remove the cover
inside of the cart
■Image as seen from the
arrow direction
4
Adjust the pressure to be
within the range
5
Cleaning blow regulator
knob
● How to use the regulator knob
1: Pull the knob up
2: Adjust it
3: Pull it down
(For cleaning blow pressure)
4-1-1-6
●Screw: Four locations
●Remove screws
Vacuum break
pressure regulator
knob
Lock nut
●When the vacuum break regulator
is adjusted, loosen the lock nut.
After adjusted, tighten the nut.
Cleaning blow air
pressure
(0.13 ~ 0.14 MPa)
Cover
Every
24
hours
PeriodicPeriodic
inspection