N7201A617E00_0317 - 第138页
NPM-W 2 EJM7DE-MB-04 M-00 4-1-2 -1 Tool used: None Time required: One minutes (per location) Desc ribes inspec tion of the d ummy di spensing tape. ● For the rear side, 1 ● The head moves to the exchange position. 3 Befo…

NPM-W2 EJM7DE-MB-04M-00
Front side
Remove the cover
inside of the cart
■Image as seen from the
arrow direction
4
Adjust the pressure to be
within the range
5
Cleaning blow regulator
knob
● How to use the regulator knob
1: Pull the knob up
2: Adjust it
3: Pull it down
(For cleaning blow pressure)
4-1-1-6
●Screw: Four locations
●Remove screws
Vacuum break
pressure regulator
knob
Lock nut
●When the vacuum break regulator
is adjusted, loosen the lock nut.
After adjusted, tighten the nut.
Cleaning blow air
pressure
(0.13 ~ 0.14 MPa)
Cover
Every
24
hours
PeriodicPeriodic
inspection

NPM-W2 EJM7DE-MB-04M-00
4-1-2-1
Tool used: None Time required: One minutes (per location)
Describes inspection of the dummy dispensing tape.
●For the rear side,
1
●The head moves to the
exchange position.
3
Before
opera-
tion
Maintenance
4-1-2
Checking the dummy
dispensing tape
(dispensing head(option))
OFF
SERVO
2

NPM-W2 EJM7DE-MB-04M-00
4-1-2-2
Visually check the remaining amount of tape
4
●At this time, also check
for slack in the tape.
If tape slack is found,
turn the feed side reel in
a counterclockwise to
take up the slack.
Dummy dispensing tape
Feed side Tape-up
side
SERVO
ON
5
6
Every
24
hours
PeriodicPeriodic
inspection