NPM-W 2 EJM7DE-MB-04 M-00 4-2-5 -5 Cleaning the screw unit 2 ■ Example of cleaning ● If the nozzle inside is clogged with adhesive, remove it with a pin, drill, or wire that matches the nozzle hole diameter. ● Check for …

100%1 / 572
NPM-W2 EJM7DE-MB-04M-00
4-2-5-4
Cleaning the screw unit 1
10
11
Disconnect the
screw unit from
the syringe
(counterclockwise)
Disassemble the screw unit
Turn the top cap in a clockwise
and turn the bottom cap in a
counterclockwise to remove.
Do not remove the screws.
12
To
15
Bottom cap
Top cap
Screw
Wipe adhesive
on each part off
using a lint free
cloth
13
Wipe the adhesive in the screw shaft using an
air blow gun
Cover the part when using
an air blow gun because
adhesive will scatter in all
directions.
14
Clean the parts for three minutes with an
ultrasonic cleaner
Having the water level of the ultrasonic
cleaner tank at 1 cm, place a beaker
containing cleaning solvent (e.g. alcohol,
etc.) into the ultrasonic cleaner.
Put the parts inside the beaker. (The
amount of cleaning solvent inside the
beaker should be sufficient to let all parts
sink under the solvent.)
The cleaning time should not exceed 5
minutes.
(Even cleaning for 5 minutes or more brings
about the same effect.)
1 cm
Every
24
hours
PeriodicPeriodic
inspection
NPM-W2 EJM7DE-MB-04M-00
4-2-5-5
Cleaning the screw unit 2
Example of cleaning
If the nozzle inside is clogged with adhesive, remove it with a
pin, drill, or wire that matches the nozzle hole diameter.
Check for any adhesive on and around the O-ring.
Using the swab of P751S sometimes sticks into the screw
shaft. Use the stick side of the swab to clean inside of the
screw shaft.
NOTICE
Please replace the O-ring if it is cracked or deteriorated.
Usethefollowingindustrialswabsforprecisionmachineforcleaning.
After
opera-
tion
Maintenance
4-2-5
Cleaning and checking the
screw unit and the nozzles 3
(dispensing head(option))
Nozzle holder
Screw shaft
When adhesive residue found on a
swab to wipe the part is reduced to a
relatively small amount as shown above,
any remaining adhesive will not affect
the dispensing accuracy.
15
Take the parts out and clean each part with a
swab
Dispensing nozzle
Model model No. Remarks
751S
N986P751S
200 pieces
NPM-W2 EJM7DE-MB-04M-00
4-2-5-6
16
17
Blow away
alcohol with an
air blow gun to
dry them
Assemble the screw unit back and check the
condition of cleaned parts
No clogging in the tip
No adhesive stuck on the tip
No adhesive stuck on the
outer surface
No adhesive stuck on the
reference plane
No bends in the nozzle and
the stopper
Remaining alcohol will
harden the adhesive.
They should be dried
completely.
To
19
1
2
5
3
4
18
Set the screw unit to the syringe
(Clockwise)
Every
24
hours
PeriodicPeriodic
inspection