NPM-W 2 EJM7DE-MB-04 M-00 4-2-5 -7 Attaching the syringe 19 Set the screw unit to the syringe holder After opera- tion Maintenance 4-2-5 Cleaning and c hecking the scr ew unit and the no zzles 4 (dispensing head(option))…

100%1 / 572
NPM-W2 EJM7DE-MB-04M-00
4-2-5-6
16
17
Blow away
alcohol with an
air blow gun to
dry them
Assemble the screw unit back and check the
condition of cleaned parts
No clogging in the tip
No adhesive stuck on the tip
No adhesive stuck on the
outer surface
No adhesive stuck on the
reference plane
No bends in the nozzle and
the stopper
Remaining alcohol will
harden the adhesive.
They should be dried
completely.
To
19
1
2
5
3
4
18
Set the screw unit to the syringe
(Clockwise)
Every
24
hours
PeriodicPeriodic
inspection
NPM-W2 EJM7DE-MB-04M-00
4-2-5-7
Attaching the syringe
19
Set the screw unit to the syringe holder
After
opera-
tion
Maintenance
4-2-5
Cleaning and checking the
screw unit and the nozzles 4
(dispensing head(option))
Adjust the guide pin of the screw unit to the 9 to 11 o’clock
position. Then insert it into housing.
Housing groove
1
2
Rotate the screw in the clockwise direction until it stops
rotating.
Push the syringe in until it hits, with the angle of the flange
adjusted according to the holder direction.
Flange
Guide pin
By moving it to the 9 to 11 o’clock position in the clockwise
direction, the guide pin is fitted into the groove of the
housing.
NPM-W2 EJM7DE-MB-04M-00
4-2-5-8
20
Check that the lock plate comes to the lock position.
21
Lock plate
Connect the air
plug
22
Take out the
cloth covered
with the multi-
recognition
camera and the
nozzle changer
23
Rotate the lock plate in the counterclockwise direction, and
lock the syringe
SERVO
ON
24
Every
24
hours
PeriodicPeriodic
inspection