N7201A617E00_0317 - 第172页
NPM-W 2 EJM7DE-MB-05 M-00 Cleaning the f eeder table (feeder cart, 13-slot feeder (option)) Maintenance 5-5 5-5 1 2 4 5 3 Clean the feeder table ● Clean the feeder installation face after removing tape feede rs. (A cause…

NPM-W2 EJM7DE-MB-05M-00
Attach the
feeder cart
(→P.3-2)
Cleaning the cover
glass (multi-recognition camera)
Maintenance
5-4
5
Remove a foreign body including dust
from the cover glass
●Be sure not to deform the
light resistance plate.
(Deformation could cause
recognition errors)
Describes cleaning of the multi-recognition camera’s cover glass.
Tool used: Lint free cloth Time required: 5 minutes (Total time required for both the front and rear sides)
●If you clean the cover glass of the machine whose rear side is tray specifications, use a step ladder as
necessary.
3
5-4
●Be careful not to scratch
the cover glass surface
while cleaning it with a soft
lint free cloth. (Scratches
may hinder proper image
capture)
Cover glass
Light resistance plate
8
1
Detach the
feeder cart
(→P.3-2)
6
4
Push the X-axis
beam inward
OFF
SERVO
2
SERVO
ON
7
Every
140
hours
PeriodicPeriodicPeriodic
inspection

NPM-W2 EJM7DE-MB-05M-00
Cleaning the feeder table
(feeder cart, 13-slot feeder (option))
Maintenance
5-5
5-5
1
2
4
5
3
Clean the feeder table
●Clean the feeder installation face after removing tape feeders.
(A cause of deformation in the feeder cart.)
●Clean the feeder table using a
vacuum cleaner or brush.
●Do not use an air blow gun in cleaning.
(A foreign body including dust could scatter inside the machine,
thus worsening placement quality, or breaking down the
machine.)
Describes cleaning of the feeder table
Tool used: Vacuum cleaner, brush Time required: 15 minutes per location
Feeder table
■13-slot feeder
■Feeder cart
OFF
SERVO
SERVO
ON

NPM-W2 EJM7DE-MB-05M-00
5-6
Cleaning the table
surface
(tray feeder drawer (option))
Maintenance
5-6
Describes cleaning of the table surface of the tray feeder drawer.
Tool used: Lint free cloth Time required: 5 minutes
●Before cleaning it, ensure that the magazine is removable. (→P.6-14)
OFF
SERVO
SERVO
ON
6
7
1
32
4
5
For the twin tray
feeder, choose
the table
or
ENABLING
(The tray feeder drawer
moves to the maintenance
position)
Clean the table surface
●Wipe off with a soft lint free cloth.
Tray feeder drawer
table surface
Every
140
hours
PeriodicPeriodicPeriodic
inspection