N7201A617E00_0317 - 第189页
NPM-W 2 EJM7DE-MB-06M-00 6-2 -8 Every 560 hours Periodic Periodic Periodic Periodic inspection

NPM-W2 EJM7DE-MB-06M-00
6-2-7
Attach the
feeder cart
(→P.3-2)
Greasing the XY-axis
linear guide 4
Maintenance
6-2
Wipe off the
grease that ran
out of the
edging
●See steps and .
●Check linear guide rail edge
and grease nipples whether
any liquefied grease is
adhered; if any has, wipe on
a regular basis.
10
11
30
32
SERVO
ON
33
(Front and rear)
34
31
(Front and rear)

NPM-W2 EJM7DE-MB-06M-00
6-2-8
Every
560
hours
PeriodicPeriodicPeriodicPeriodic
inspection

NPM-W2 EJM7DE-MB-06M-00
Explains the method for greasing the nozzle holder using the 12-nozzle head as an example; however, the
same procedure is also applicable to the light weight 16-and 8-nozzle head.
Tool used: Syringe (BARRIERTA IEL/V)
Time required: 20 minutes for light weight 16-nozzle head, 15 minutes for 12-nozzle head, and 10 minutes for
8-nozzle head.
2
1
Greasing the nozzle
holder
Detach the
nozzle holder
(→P.5-2)
Refill grease to the oil groove at the clamp
claw
●With the clamp claw attached, apply grease using a small flat-
head screwdriver.
(To prevent grease from adhering to the portions around the
clamp claws)
●Grease: BARRIERTA IEL/V
●Wipe off any grease adhering to portions other than the oil
groove using a cotton swab.
●Be careful no grease adheres to the filter on the nozzle holder tip.
●Ensure that clamp claws are inserted to oil grooves before
installing the nozzle holder to the transfer head.
3
Apply grease to the contact surface of the
clamp claw and the spring for the clamp claw
pusher
●Apply grease lightly using a syringe.
●Grease: BARRIERTA IEL/V
6-3
Contact
surface
Clamp claw
Grease
Oil
groove
Clamp claw
Maintenance
6-3