N7201A617E00_0317 - 第214页

NPM-W 2 EJM7DE-MB-06M-00 Tool used: Swabs, Allen wrench (3 mm) Time required: 5 minutes Extension conveyor (option) Cleaning the PCB detection sensor s 2 Maintenance 6-9 Detach the feeder cart ( → P.3-2) Adjust the conve…

100%1 / 572
NPM-W2 EJM7DE-MB-06M-00
6-9-2
4
6
5
Every
560
hours
PeriodicPeriodicPeriodicPeriodic
inspection
Hold the feeder
table cover to
the back
Clean the PCB
detection sensors
Six PCB detection sensors
Transparency type: Four sets
(a pair of the light-emitting side
and the light-receiving side)
Reflection type: Two sets
PCB detection sensor
(Reflection type)
PCB detection sensor
(Transparency type)
PCB conveyor
For single conveyor
Five PCB detection sensors on each
lane
Transparency type: Four sets
(a pair of the light-emitting side
and the light-receiving side)
Reflection type: Two sets
For dual conveyor
Use swabs.
Neither lean against the
feeder table cover nor place
anything on it.
NPM-W2 EJM7DE-MB-06M-00
Tool used: Swabs, Allen wrench (3 mm) Time required: 5 minutes
Extension conveyor (option)
Cleaning the PCB
detection sensors 2
Maintenance
6-9
Detach the
feeder cart
(P.3-2)
Adjust the
conveyor
width of 150mm
([Operating
procedure] P.2-5-4)
For better workability
1
2
OFF
SERVO
3
SERVO
ON
10
9
8
7
Attach the
feeder cart
(P.3-2)
Return the
feeder table
cover back
6-9-3
NPM-W2 EJM7DE-MB-06M-00
6-9-4
4
Sensor position installed to the upstream process of the dual conveyor
Clean the PCB detection sensors using a swab
Use a swab.
Every
560
hours
PeriodicPeriodicPeriodicPeriodic
inspection
4
5
Hold the feeder table cover to the back
Sensor position installed to the upstream process of the single conveyor
A
(Reflection type)
PCB detection sensor
View on arrow A
A
B
View on arrow AView on arrow B
(Reflection type)
PCB detection sensor
(Reflection type)
PCB detection sensor
If it is difficult to perform the work,
remove the feeder table cover.
Neither lean against the feeder
table cover nor place anything on
it.