NPM-W 2 EJM7DE-MB-08M-00 8-2 -4 Every 3000 hours Periodic Periodic Periodic Periodic Periodic inspection

100%1 / 572
NPM-W2 EJM7DE-MB-08M-00
8-2-3
Attach the filter
11
Maintenance
8-2
Attach the filter to the filter
holder, insert the joints into
the four fan-installation
grooves, and attach the
filter holder.
Filter holder
12
13
14
ON
Attach the cover of the FA computer
Align the three right claws of the cover with the
appropriate positions on the case, align the three
left claws in the same way, and finally press in the
entire cover.
Attach the front
cover of the
inspection box
Attach the front cover of
the inspection BOX with
an Allen wrench.
Secure the front cover
with eight screws.
Cleaning the filter of
the FA computer 2
(inspection box(option))
NPM-W2 EJM7DE-MB-08M-00
8-2-4
Every
3000
hours
PeriodicPeriodicPeriodicPeriodicPeriodic
inspection
NPM-W2 EJM7DE-MB-08M-00
Describes how to replace the O-ring.
Tool used: Allen wrench Time required: 20 minutes
Even if the consumable parts replacement cycle has not ended, be sure to replace the O-ring if it is
cracked or deteriorated.
Total four O-rings are used for these sections; one for a syringe holder section, one for a joint section and
two for a screw unit section.
Replacing the O-ring 1
(dispensing head(option))
Maintenance
8-3
Joint
Screw unit Syringe holder
O-ring
8-3-1
Personnel with pacemakers should keep away from the linear
motor
(Risk of accidents caused by errors in operation due to magnetic force)
WARNING