NPM-W 2 EJM7DE-MB-08 M-00 Describes how to replace the O-ring. Tool used: Allen wrench Time required: 20 minutes ● Even if the consumable parts replaceme nt cycle has not ended, be sure to replace the O-ring if it is cra…

100%1 / 572
NPM-W2 EJM7DE-MB-08M-00
8-2-4
Every
3000
hours
PeriodicPeriodicPeriodicPeriodicPeriodic
inspection
NPM-W2 EJM7DE-MB-08M-00
Describes how to replace the O-ring.
Tool used: Allen wrench Time required: 20 minutes
Even if the consumable parts replacement cycle has not ended, be sure to replace the O-ring if it is
cracked or deteriorated.
Total four O-rings are used for these sections; one for a syringe holder section, one for a joint section and
two for a screw unit section.
Replacing the O-ring 1
(dispensing head(option))
Maintenance
8-3
Joint
Screw unit Syringe holder
O-ring
8-3-1
Personnel with pacemakers should keep away from the linear
motor
(Risk of accidents caused by errors in operation due to magnetic force)
WARNING
NPM-W2 EJM7DE-MB-08M-00
The explanation in the following procedure is an example when the dispensing head is installed on the
rear side and operated from the front side.
Please remove the syringe before work.(P.4-2-5)