N7201A617E00_0317 - 第281页

10 Periodic inspection Every-18000-hours

100%1 / 572
NPM-W2 EJM7DE-MB-09M-00
Inspecting the 1006
nozzle (option)
Maintenance
9-3
Tool used: None Time required: 1 minute
Clamp groove
Confirm whether clamp grooves wear out or not.
(To prevent from decreasing clamping force after long time use)
Replace it after 6000 hours (a year) or 700000 times of automatic nozzle changer of operation. It is
recommended that you stock spare nozzles.
9-3
10 Periodic inspection
Every-18000-hours
NPM-W2 EJM7DE-MB-10M-00
4
When there is no
damage or wear out
Inspecting the nozzle
holder (option)
10-1-1
Maintenance
10-1
Tool used: None
Time required: 20 minutes for light weight16-nozzle head, 15 minutes for 12-nozzle head and 10 minutes for
8-nozzle head (per head)
7
Attach the spring for nozzle cushion
(For 12-/8-nozzle head)
5
Attach the spring
for holding
clamp claws
6
Check that the claws are
securely engaged in the
grooves in the nozzle
holder.
Push in the
clamp claw
1
Remove the spring for nozzle cushion
2
3
Pull out the
clamp claws
Remove the
spring for holding
clamp claws
Spring for
nozzle
cushion
Clamp claws
Spring for
holding
clamp claws
Light weight16-/12-/8-nozzle head
Spring for
holding
clamp claws
Check the part,
and if any
damage or wear
out is found,
replace it
Clean it and apply
grease (P.7-1)
For 12-/8-nozzle head
For light weight16-nozzle
head
(Do not remove)
Twist the spring to remove.
If any part wears out, it may cause pickup error or placement error. So , please inspect them after using
about 18000 hours. If any part wears out, replace it. We recommend replacing all parts at the same time.
Groove in
nozzle
holder