N7201A617E00_0317 - 第330页
NPM-W 2 EJM7DE-MB-12M-00 Maintenance 12-5 3 OFF SERVO 1 2 Push the X-axis inward R eplacing the cushion (wiping sta tion) (dispensing head(option)) 4 5 6 SERVO ON 7 8 Tool used: None Time required: 1minute ● When the cus…

NPM-W2 EJM7DE-MB-12M-00
4
Detach the
dummy
dispensing unit
5
Detach two
stoppers
6
Stoppers
Detach the old
tape
Tape-up side
Feed side
●Keep a paper core of a
feed side and do not
throw it away. It is used
for rolling up a new tape.
8
Put a new tape to a feed side
7
Put the paper
core of an old
tape to take-up
side
●Dummy dispensing tape:
N210112529AA
●Attention to the rotation
direction of a dummy
dispensing tape
Tape-up side
Feed side
12-4-2
1
2
①Tilt the attachment lever to
the left
②Detach the dummy
dispensing unit
Consumable parts
replacement

NPM-W2 EJM7DE-MB-12M-00
Maintenance
12-5
3
OFF
SERVO
1
2
Push the X-axis
inward
Replacing the cushion
(wiping station)
(dispensing head(option))
4
5
6
SERVO
ON
7
8
Tool used: None Time required: 1minute
●When the cushion (wiping station) is broken or seriously contaminated, replace it according to the following
steps.
Remove the
cushion (wiping
station)
Replace the old
cushion (wiping
station) to new
one
Put the cushion
(wiping station)
back to the
original position
●Cushion (wiping station):
N610116409AA
●Make sure that the
cushion (wiping station) is
properly placed. If it is
mounted on the frame
and placed, it may
damage a nozzle during
operation.
12-5-1

NPM-W2 EJM7DE-MB-12M-00
Consumable parts
replacement
12-5-2