N7201A617E00_0317 - 第352页

NPM-W 2 EJM7DE-MB-13M-00 Choose a table ● Choose the table to calibrate. 2 + 1 Head camera XY origin Explains the method for calibrating the head camera’s XY origin, taking for an example, the 12-nozzle head; however, th…

100%1 / 572
NPM-W2 EJM7DE-MB-13M-00
13-1-4-2
Calibration
NPM-W2 EJM7DE-MB-13M-00
Choose a table
Choose the table to calibrate.
2
+
1
Head camera XY origin
Explains the method for calibrating the head camera’s XY origin, taking for an example, the 12-nozzle head;
however, the same method can also be applied to the light weight 16-, 8-, and 3-nozzle heads.
You must operate the machine under the pre-operation status in the following environmental conditions;
temperature: 10 to 35 and humidity: 25 to 75 % RH.
(The camera angle is calibrated)
Confirm that it has been
successfully completed
+
(The XY origin camera scale is
calibrated)
12
3
13-2-1
3
Maintenance
13-2
NPM-W2 EJM7DE-MB-13M-00
13-2-2
Confirm the message
6
6
When you do not save the data
To cancel
(The screen remains as it is in . )
5
Confirm the message
7
(XY unit moves to the origin)
+
7
Confirm that it has been
successfully completed
4 5
4
5
Perform steps to for the
other table.
1
4
Calibration