NPM-W 2 EJM7DE-MB-13M-00 13-4 -9 Maintenance 13-4 Head / Plane calibr a tion Z 5 Dispensing head 2 11 11 Confirm that it has been successfully completed 12 13 (The head moves to the work position) + Confirm the message 1…

100%1 / 572
NPM-W2 EJM7DE-MB-13M-00
13-4-8
Calibration
8
(The head moves to the work position)
+
Confirm that it has been
successfully completed
If it has been successfully completed,
the display of each nozzle position is
changed from '-' to 'OK'.
6
6
7
8
9
10
Confirm the message
+
(Completes plane correction Z)
(The head moves to the work position)
+
Confirm that it has been
successfully completed
(The Dummy dispensing height is
calibrated)
Confirm the message
+
Confirm that it has been
successfully completed, and
choose the other nozzle
positions for plane correction
Z and then repeat steps from
to
2
9
10
NPM-W2 EJM7DE-MB-13M-00
13-4-9
Maintenance
13-4
Head / Plane
calibration Z 5
Dispensing head 2
11
11
Confirm that it has been
successfully completed
12
13
(The head moves to the work position)
+
Confirm the message
12
Confirm the message
(The plane correction Z data is saved)
ATTENTION
When this calibration is performed, adhesives may stains to the reference post or on
the rail. If so, please wipe it off with a cloth.
NPM-W2 EJM7DE-MB-13M-00
13-4-10
Calibration