NPM-W2 EJM7DE-MB-13M-00
The surface height of several points on the PCB top surface is measured by the height sensor, and
according to the result, PCB warpage condition is predicted and the nozzle lowering position is controlled
for placement operation. This operation procedure is also shared by the light weight 16-, 12-, 8- and 3-
nozzle heads. Remove all support pins before performing calibration.
Maintenance
13-7
13-7-1
Height sensor (option) 1
Select a table
Select a table to perform calibration.
(Work only at the front side)
+
12 3
(Confirm whether any PCB remains on
the transfer rail)
If there is PCB, remove it followed by
the instruction on the screen.
Confirm the message
When you do not work
(The head remains as it is in )
1
Servo switch OFF
Open the safety cover
Remove the PCB-support pin as
necessary
([Operating procedure] P.2-5-3)
1
2
3
4
6
5
7
4
(The width is adjusted)
(The head moves to the retraction position)
NPM-W2 EJM7DE-MB-13M-00
13-7-2
Slide and set the height teaching
jig from the standby side
For calibration of the height sensor,
jigs on both the front and rear heads
are set to lane 1.
Push the jig to the fixed side on the
rail, and set the jig as the right edge of
the jig matches to the mark on the
conveyor. (The picture on the left is for
left to right flow.)
For right to left flow, the left edge of
the jig shall be matched to the mark on
the conveyor
Close the safety cover
Servo switch ON
+
(The head moves to the set position)
Servo switch OFF
Open the safety cover
Confirm that there is no contamination
or stain on the measurement part
: PCB flow direction
Reference mark
(Leftright flow)
Conveyor side
Mark (φ1 hole)
Measurement part
teaching jig
Reference mark
(Right left flow)
Conveyor side
Mark (φ1 hole)
Calibration
11
8
9
10
13
12
11
NPM-W2 EJM7DE-MB-13M-00
+
(The head operates for measurement)
Close the safety cover
Servo switch ON
Maintenance
13-7
13-7-3
Nozzle
Confirm the message and
install the nozzle
(The screen show for light weight16-
nozzle head)
Head
type
Nozzle
position
Nozzle
type
16 No. 5
230CS
12 No. 4
8 No. 3 230C
3No. 21003
For the dispensing head, it is
necessary to install the screw unit that
a calibration nozzle (nozzle no. 7202)
is previously set to the nozzle position
2.
Height sensor (option) 2
14
18
15
16
17
18
17
14
(The screen show for light weight16-
nozzle head)