N7201A617E00_0317 - 第381页
NPM-W 2 EJM7DE-MB-13M-00 13-7 -4 Calibration Confirm that it has been successfully completed Pressing other menu screen appears confirmation message of data save (The d ata obtained by ca libration is cleared (The d ata …

NPM-W2 EJM7DE-MB-13M-00
+
(The head operates for measurement)
Close the safety cover
Servo switch ON
Maintenance
13-7
13-7-3
●Nozzle
Confirm the message and
install the nozzle
(The screen show for light weight16-
nozzle head)
Head
type
Nozzle
position
Nozzle
type
16 No. 5
230CS
12 No. 4
8 No. 3 230C
3No. 21003
●For the dispensing head, it is
necessary to install the screw unit that
a calibration nozzle (nozzle no. 7202)
is previously set to the nozzle position
2.
Height sensor (option) 2
14
18
15
16
17
18
17
14
(The screen show for light weight16-
nozzle head)

NPM-W2 EJM7DE-MB-13M-00
13-7-4
Calibration
Confirm that it has been
successfully completed
Pressing other menu screen
appears confirmation message
of data save
(The data obtained by calibration is
cleared
(The data obtained by calibration is
saved)
■When you do not save
■To cancel
(The screen remains as it is in )
Remove the nozzle
Servo switch OFF
Open the safety cover
Close the safety cover
19
20
22
21
23
24
19
19
20
(The head moves to the work position)

NPM-W2 EJM7DE-MB-13M-00
13-7-5
Maintenance
13-7
Height sensor (option) 3
+
■When you do not remove the nozzle
(The head remains as it is in )
Servo switch ON
+
■When you do not remove the jig PCB
(The screen remains as it is in )
Remove the height sensor jig
Close the safety cover
Open the safety cover
(Confirm whether any PCB remains on
the transfer rail)
Servo switch OFF
Servo switch ON
26
25
32
29
30
31
28
27
19
26
32
19
(The head moves to the retraction position)