N7201A617E00_0317 - 第387页

NPM-W 2 EJM7DE-MB-13M-00 Install nozzles Close the safety cover ● Install them to the nozzle positions to be measured. (Use 1003 nozzle) Servo switch ON 13-8-1 -4 Calibration ● Reads a stable numerical value being measur…

100%1 / 572
NPM-W2 EJM7DE-MB-13M-00
Place-
ment
load
13-8-1-3
Placement load 2
+
Confirm the message
To cancel
(The screen remains as it is in )
1
(Each time you press it, the nozzle
position No. changes)
Choose the position to perform
calibration.
+
Maintenance
13-8-1
Servo switch OFF
Open the safety cover
Prepare to install nozzles
11
12
13
15
16
14
11
12
13
(The head moves to the work position)
NPM-W2 EJM7DE-MB-13M-00
Install nozzles
Close the safety cover
Install them to the nozzle positions to
be measured.
(Use 1003 nozzle)
Servo switch ON
13-8-1-4
Calibration
Reads a stable numerical value being
measured.
Load meas displays the standardized
value rather than the maximum value
since the numerical value goes up
momentarily when the nozzle and the
jig come in contact with each other so
that it becomes difficult to read the
measurement value accurately.
How to change the load cell meter
display. (P.13-8-2)
+
(Calibration is carried out)
+
Confirm the message
To cancel
(The screen remains as it is
in )
17
18
19
21
20
12
21
20
NPM-W2 EJM7DE-MB-13M-00
Confirm that it has been
successfully completed
Press the numerical part
(The numerical keypad appears)
13-8-1-5
Place-
ment
load
Placement load 3
Maintenance
13-8-1
Enter the measured value
Enter the value read in .
Input range: 3.2 to 6.2 N
Reads a stable numerical value being
measured.
Load meas displays the standardized
value rather than the maximum value
since the numerical value goes up
momentarily when the nozzle and the
jig come in contact with each other so
that it becomes difficult to read the
measurement value accurately.
How to change the load cell meter
display (P.13-8-2)
+
(Calibration is carried out)
22
23
24
25
21
22
23
24
25